Page 10
Operating Instructions PCIe TS
Check the “Service status” message. If it is not “The service is running” then
most likely the
PCIe TS board was not found. This may happen if more than one Plura PCL boards are
installed to the PC, in this case the hardware address needs to be adjusted and the service
started manually.
Click “Settings”.
The PCIe TS board
can be selected with “Hardware / LTC board base address”
. If the PCIe TS
is the only PCL board installed, this parameter is always 1. Otherwise the board can be
selected here but then the TimeSys service needs to be started
manually, see chapter “
Plura
TimeSys S
ervice”.
The other parameters may be set at a later time, for details please refer to chapter
“Monitor
Program / Settings”
.
Click “OK” to sav
e the settings and close the window.