Operating the regulator
This section briefly describes how the
regulator should be operated.
8.1
Description of panel operation
The regulator is operated by touch buttons
that allow you to select items from the menu
and edit parameters.
1.
MENU entry button
2.
The parameter selection button from the
list, increasing the value of the edited
parameter and switching main screen
3.
ENTER button
4.
EXIT button
5.
The parameter selection button from the
list, reducing the value of the edited
parameter and switching the main
screens.
8.2
Description of display main
window
1.
regulator operation modes: FIRE-UP,
STABILIZATION,
OPERATION,
SUPERVISION, BURNING OFF, STOP,
CHIMNEY
2.
boiler preset temperature
3.
boiler measured temperature
4.
functions having influence on preset
boiler temperature. Following symbols
signal respectively:
,,T” Preset boiler temperature decrease
due to thermostat disconnection.
,,S” Preset boiler temperature decrease
due to activated time intervals.
,,C” Boiler preset temperature during
loading the hot water (HUW).
,,M” Increase of the preset temperature
of the boiler from the mixer circuit.
,,P” Weather control switch on for boiler
circulation.
„B” Preset temperature increase to load
the buffer.
5.
symbol signalling fan operation
6.
symbol signalling main feeder operation
7.
symbol signalling central heating (CH)
pump operation
8.
symbol signalling central heating pump
operation (HUW)
9.
measured temperature of hot water boiler
(HUW)
10.
preset
hot
water
(HUW)
boiler
temperature
11.
clock and weekday
12.
Part of the screen coshared between two
icons:
“match” – symbolizes operating heater,
and the digit next to it stands for a
number of Firing-upattempts,
“poker”
–
symbolizes
activating
automatics of furnace cleaning.
13.
external (weather) temperature
14.
symbol signalling disinfection of the hot
water boiler
15.
symbol
signalling
additional
feeder
operation.
Right window on the main screen is
configurable, allows on changing information
displayed there. It is possible to choose a
configuration displaying.
Right window on the main screen may also
display the fuel level view, providing that this
parameter is set correctly.
Note: Fuel level can be seen in room panel
ecoSTER200 and ecoSTER TOUCH.
8.3
Switching on and off the boiler
After connecting the power the regulator
shows the settings put before connecting the
electricity. If the regulator has not operated
before – it will start up in „Stand-by” mode.
In this mode the screen is dimmed, actual
time and information: Boiler Off is displayed.
Mon
8
13
11
10
9
14
12
7
6
5
2
4
1
3
OPERAT
15
Содержание ecoMAX860P3-LZ
Страница 6: ...6 ...
Страница 7: ...INSTRUCTION MANUAL ecoMAX860P3 LZ ...
Страница 17: ...INSTALLATION AND SERVICE SETTINGS ecoMAX860P3 LZ ...
Страница 41: ...41 ...
Страница 42: ...42 ...
Страница 43: ...43 ...
Страница 44: ...ul Wspólna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl ...