30
Connecting emission sensor: 1 – exhaust temp.
sensor type CT2S, 2 – sensor lead, 3 – flue.
Caution: Opening the boiler door
can
cause
the
emission
temperature to exceed the sensor‘s
thermal resistance, which can burn
the sensor out.
12.11
Temperature sensors
checking
Temperature sensors can be checked by
measuring
their
resistance
in
given
temperature. In case of big differences
between measured resistance value and
values in table below, the sensor should be
replaced with a new one.
CT4
Temp.
°C
Min.
Ω
Nom.
Ω
Max.
Ω
0
802
815
828
10
874
886
898
20
950
961
972
25
990
1000
1010
30
1029
1040
1051
40
1108
1122
1136
50
1192
1209
1225
60
1278
1299
1319
70
1369
1392
1416
80
1462
1490
1518
90
1559
1591
1623
100
1659
1696
1733
CT6-P (weather)
Temp.
°C
Min.
Ω
Nom.
Ω
Max.
Ω
-25
901,6
901,9
902,2
-20
921,3
921,6
921,9
-10
960,6
960,9
961,2
0
999,7
1000,0
1000,3
25
1096,9
1097,3
1097,7
50
1193,4
1194,0
1194,6
100
1384,2
1385,0
1385,8
125
1478,5
1479,4
1480,3
150
1572,0
1573,1
1574,2
CT2S-2 (exhaust)
Temp.
°C
Min.
Ω
Nom.
Ω
Max.
Ω
0
999,7
1000,0
1000,3
25
1096,9 1097,3
1097,7
50
1193,4 1194,0
1194,6
100
1384,2 1385,0
1385,8
125
1478,5 1479,4
1480,3
150
1572,0 1573,1
1574,2
12.12
Connection of optical sensor
The optical sensor should be connected in
accordance with the electric scheme,
maintaining the polarization of the SYG (+)
and GND (-) signals of the sensor. Reading
from the flame optical sensor is possible in
the menu:
Information
→
Flame
Incorrect connection of the optical
sensor
will
not
damage
the
controller or the sensor itself, but
the burner flame detection will be
incorrect.
12.13
Connection of mixers room
temperature
Room thermostat after disconnecting wires
reduces preset temperature of the value of
reduction the preset temperature of the
mixer from the thermostat. Parameter is in
the menu:
Mixer settings 1-5
→
Mixer room
temperature
Value of parameter should be chosen in such
a way that after activating room thermostat,
temperature in the room should decrease. In
case of room panel make sure that this
220°C
Содержание ecoMAX860P3-KL
Страница 6: ......
Страница 7: ...USER SETTINGS ecoMAX860P3 KL...
Страница 18: ...18...
Страница 19: ...19 INSTALLATION AND SERVICE SETTINGS ecoMAX860P3 KL...
Страница 44: ...44...
Страница 45: ...45...
Страница 46: ...46...
Страница 47: ...47...
Страница 48: ...48 ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www pum pl...