TR-4-2
28 May 2009
TR-001
Fault Code TR-001, indicates that the Transport motor (TR-M1) does not receive any displacement
pulses.
Initial Actions
Check fuse F2 on Transformer.
Make sure that the Transport belt sensor (TR-Q4) is installed correctly (
TR 3.2.5).
Procedure
Enter the Service mode and select Transport motor (TR-M1) in check motors.
Does the encoder run properly, Parts catalog
page 13, Item 17?
Y
N
1. Check transmission (
3.2.17).
2. Replace motor TR-M1.
1. Replace sensor TR-Q4.
2. Disconnect plug B.P14 from PCB “A”. Measure between J14-13 and J14-15? (5V and ground).
The voltage is
approximately 5 VDC?
Y
N
Replace PCB “A”.
Disconnect plug from sensor TR-Q4. Check wires for Continuity / Short circuit from the white wire Q4 to B.P14-14.
Is there
Continuity and no Short circuit?
Y
N
Replace Wire Harness
Connect plug B.P14 to PCB “A”. Measure between the red wire Q4 and the black wire Q4 (5V and ground).
The voltage is
approximately 5 VDC?
Y
N
Replace wire Harness.
Replace PCB “A”.
FAULT CODE DESCRIPTIONS
Содержание TR5010e
Страница 1: ...TRIMMER TR5010e SERVICE MANUAL 4 August 2009 Subject to change...
Страница 2: ...Page intentionally blank...
Страница 6: ...Page intentionally blank...
Страница 8: ...Page intentionally blank...
Страница 31: ...Replacement Adjustment Page intentionally blank...
Страница 44: ...Page intentionally blank...
Страница 46: ...Page intentionally blank...
Страница 60: ...TR 4 14 Page intentionally blank...
Страница 62: ...Page intentionally blank...
Страница 66: ...TR 6 4 28 May 2009 6 1 3 OUTFEED VIEW TR Q6 TR M2 TR M1 ELECTRICAL COMPONENT LIST...
Страница 68: ...Page intentionally blank...
Страница 69: ...Detailed description TR 6 7 28 May 2009 6 2 BOARD STRUCTURE 6 2 1 BLOCK DIAGRAM Interlock magnet...
Страница 72: ...Page intentionally blank...
Страница 78: ...Page intentionally blank...
Страница 79: ...TR Wir 1 28 May 2009 Wiring WIRING Trimmer See pocket at rear of manual for wiring diagrams...
Страница 80: ...Page intentionally blank...