Installing your Alignment Plate:

Important Notice for Installer

To achieve proper aesthetic installation of the Acenti
products, the wall surface surrounding the wall box opening
must be fairly flat and free of irregularities. The wall box
must be level and recessed or flush to the wall surface. The
Acenti installation system allows for adjustments that will
correct minor flaws that may be present in the installation
area.

This device must be installed with the Acenti™ Alignment
Plate. The Alignment Plate is packaged with the Acenti™
Wallplate, which is sold separately from this device.

The Alignment Plate will function properly only if it is
mounted to a flat wall surface as described above.

• Leviton recommends to temporarily position the Alignment

Plate prior to wiring the device. If the wall box wires
extend at least 6 inches out of the wall box, it is also
possible to install the Alignment Plate after the device has
been wired (refer to Wallplate instruction sheet).

Single Pole (One location) or 3-Way (Multi-location)

Fluorescent Dimmer (Lighted)

Cat. No. ACX1Ø-1L, 1000VA

120VAC, 60Hz

For use with Mark 10™

 

Powerline and Tu-Wire

TM

 dimmable ballasts

INSTALLATION INSTRUCTIONS

Installing your Dimmer –
Single-Pole Wiring Application:

DI-000-ACX10-00A-X0

 Tools needed to install your Dimmer:

Slotted/Phillips Screwdriver

Electrical Tape

Pliers

Pencil

Cutters

Ruler

 Installing Dimmer by itself or with other devices:

If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-
device application, proceed as follows:

MULTI-DEVICE APPLICATION

In multi-dimmer installations, the reduction of the dimmer’s capacity
is required. Breaking off fins is not required on this device. Refer to
the chart for maximum load per dimmer.

WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:

Green or bare copper wire in wall box to Green dimmer lead.

Line Hot wall box wire to Black dimmer lead.

Load wall box wire to Red dimmer lead.

Line Neutral wall box wire to White dimmer lead.

Yellow/Red wire should have Red insulation label affixed.
NOTE: If insulating label is not affixed to Yellow/Red dimmer
lead, use electrical tape to cover.

Proceed to Step 6.

WARNINGS AND CAUTIONS:

To be installed and/or used in accordance with appropriate electrical codes and regulations.

If you are unsure about any part of these instructions, consult a qualified electrician.

To avoid overheating and possible damage to this device and other equipment, use only with the appropriate Advance Transformer 120V Mark 10™ 

Powerline

or Lutron Tu-Wire™ electronic ballasts for controlling the specific fluorescent lamps.

When retrofitting Mark 10™ 

Powerline dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start

sockets to allow proper dimmer operation and prevent damage to the dimmer ballast. Refer to the instructions provided with the ballast.

Acenti™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Acenti™ remotes for multi-location dimming.

Use only one (1) dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will
turn the light on at the brightness level selected at the dimmer.

WARNINGS AND CAUTIONS:

Lamps must be burned in at full intensity for 100 hours prior to dimming for proper dimming performance.

For new installations, wire a test switch before installing dimmer.

Total minimum load must exceed 40W.

Dimmer may feel warm to the touch during normal operation.

Recommended minimum wall box depth is 2-1/2".

Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.

Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.

Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.

IMPORTANT: For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a different
color (Black) or labeled Common. Tag that wire with electrical tape
and identify as the common (Line or Load) in both the dimmer wall
box and remote wall box.

For non-standard wiring applications, refer

to Wire Nut and Conductor Size Chart

MAXIMUM BULB WATTAGE:

Mark 10™

 Powerline dimmers are rated in Volt-Amps (VA). The

maximum bulb wattage is determined by the efficiency of the Mark
10™

 Powerline ballast. The following table shows the maximum

number of ballasts that can be connected to a single dimmer for
different Mark 10™

 Powerline ballasts. Also note that the table shows

maximum ballasts for multi-gang installations.

Preparing and connecting wires:

Pull off pre-cut insulation from dimmer leads. Make sure that
the ends of the wires from the wall box are straight (cut if
necessary)
. Remove insulation from each wire in the wall
box as shown.

CFM26W/GX24Q
CFM32W/GX24Q
CFM42W/GX24Q

CFQ26W/24Q

F25T8
F25T8
F25T8
F32T8
F32T8
F32T8

FT40W/2G11
FT40W/2G11

Cat. No. ACX1Ø-1, 120V, For use with

Advance Transformer 120V Mark 10™

Powerline Electronic Ballasts

Lamp

Max. # Ballasts/

Dimmer for Multi-gang

Two

Ganged

32
26
20
17
32
17
11
28
14

9

25
12

26
21
16
14
26
13

9

22
11

8

20
10

More than

2 Gang

22
18
14
12
22
12

8

19
10

7

17

9

Single
Gang

REZ-1T32
REZ-1T32
REZ-1T42
REZ-2Q26

REZ-132

REZ-2S32
REZ-3S32

REZ-132

REZ-2S32
REZ-3S32

REZ-1TTS40
REZ-2TTS40

Advance

Mark 10™
Powerline

Part No.

Lutron Tu-Wire™:

To determine total ballast load, add the line current found on the
ballast label for all ballasts in the circuit. This will indicate the total
load for the control.

Step 1

WARNING:

 TO AVOID FIRE, SHOCK, OR DEATH;

TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Identifying your wiring application (most
common):

NOTE: If the wiring in the wall box does not resemble
any of these configurations, consult a qualified electrician.

Step 2

2

4

3

1

2

4

1

5

3

3-Way

1. Line or Load

 (See important

instruction below)

2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
NOTE: For matching remote w/LEDs
installation, the First Traveler becomes
Line Hot.

Single-Pole

1. Line (Hot)
2. Neutral
3. Ground
4. Load

Step 3

Cut

(if necessary)

Strip Gage
(measure bare
wire here)

1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18

WIRE NUT / # OF COND.

COMBINATION CHART

Primary

Side

Hot (Black)

Neutral (White)

Ballast

Dimmer

Black

Insulating

Label

White

Black

White

Red

Green
Ground

Line 

120VAC, 60Hz

Yellow/Red

INSTALLING YOUR DIMMER

NOTE: Use check boxes       when Steps are completed.

5/8"

(1.6 cm)

Step 4

Step 4 cont'd

Alignment Plate

Held By Tape

Alignment Plate Held

By Mounting Screw

For Single-Pole Application, go to Step 5a.

For 3-Way Coordinating Remote (no LEDs) Application, go to Step 5b.

For 3-Way Matching Remote (with LEDs) Application, go to Step 5c.

TOP

Mounting
Screw

Alignment
Plate

TOP

Electrical
Tape

• The Alignment Plate must be installed with the tab towards

the bottom.

• Leviton recommends the following 3 methods to

temporarily hold the Alignment Plate – use of device
mounting screw, use of wall box wires, or use of electrical
tape (refer to the following figures):

Alignment Plate

Held By Wires

TOP

Step 5a

A

C

B

ACX1Ø        1000VA (8.3A)     800VA (6.6A)          650VA (5.4A)

              More than

Cat. No.

    Single

       Two Devices           2 Devices

MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE

Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove
this insulating label.

1

4

2

3

Black

White

Green

Red

Yellow/Red