background image

Plextor CD-ROM Drives

Model

Introduced

Data

Transfer Rate

Access

Time

Buffer 

Size

1st generation

DM-3020/5020

1990

150KB/sec

430ms

64K

2nd generation DM-3021/5021

1991

150KB/sec

340ms

64K

3rd generation DM-3024/5024

1992

300KB/sec

265ms

64K

4th generation DM-3028/5028

1993

335KB/sec

240ms

64K

5th generation PX-43CH/45CH

1994

600KB/sec

220ms

1MB

6th generation PX-43CS/45CS

1994

600KB/sec

170ms

256K

7th generation PX-63CS/65CS

1995

900KB/sec

145ms

256K

8th generation PX-43CE/45CE

1995

675KB/sec

130ms

256K

9th generation PX-83CS/PX-85CS

1996

1200KB/sec

115ms

256K

10th generation PX-12CE/12TE

1996

1.8MB/sec

105ms

512K

11th generation

PX-20TS

1997

1.8--3.0MB/sec

95ms

512K

12th generation

PX-32TS

1997

2--8MB/sec

85ms

512K

Plextor CD-R Drives

Model

Introduced

Max

Record

Speed

Max Data

Transfer

Access

Time

Buffer

Size

1st generation

PX-R24CS

1996

2X

600 KB/sec 390ms

512K

2nd generation

PX-R412CS

1997

4X

1.8 MB/sec 190ms

2MB

5.75" x 8.25"  PLEX WRITER MANUAL

Plextor Manual,

 Carla Williams

1/2/98

48

  PX-R412CS OPERATION MANUAL

Содержание 412-4

Страница 1: ...ter In such instances our technical support staff will try to help you identify the part e g SCSI interface board at fault and will refer you to the manufacturer of that part for further assistance Al...

Страница 2: ...mputer e g scanner fax board network board How to Contact Us There are four ways for you to contact Plextor s Technical Support Department 1 Send us e mail at support plextor com or visit our Web site...

Страница 3: ...408 945 8600 408 262 2533 408 945 7727 SCSI interface boards CD R software www adaptec com Advansys 408 383 9400 408 383 9753 408 383 9540 SCSI interface boards www advansys com AMC 425 882 0587 425...

Страница 4: ...Taiyo Yuden KODAK Ricoh Performance Data Transfer Rate CLV Write P CAV Read Sustained Read Write 12X read only 1 8MB sec Outer track 8X read only 1 2MB sec Inner track 4X read write 600KB sec 2X read...

Страница 5: ...nal SCSI Bus Two 2 50 Pin High Density Jumpers Switches SCSI ID Parity Term Test Block Size Eject Media Lock Environmental Conditions Operating Temperature 5 to 40 degrees Celsius Humidity 20 to 80 No...

Страница 6: ...er NetWare or NT networks Plextor s NetPleX network attach tower and REPleX CD tower replicator were introduced in April 1997 and the UltraPleX the first Ultra SCSI CAV CD ROM drive began shipping in...

Страница 7: ...on PX 63CS 65CS 1995 900KB sec 145ms 256K 8th generation PX 43CE 45CE 1995 675KB sec 130ms 256K 9th generation PX 83CS PX 85CS 1996 1200KB sec 115ms 256K 10th generation PX 12CE 12TE 1996 1 8MB sec 10...

Страница 8: ...es such as but not limited to damage or loss of property or equipment loss of profits or revenues cost of replacement goods or expense or inconvenience caused by service interruptions Under no circums...

Страница 9: ...986 1569 Toll Free 800 886 3935 PLEXTOR Japan 8F Kyodo building 1 4 21 Yaesu Chuou ku Tokyo Japan 103 Web Site www plextor co jp Phone 81 3 3517 8061 FAX 81 3 3517 8065 PLEXTOR Europe Excelsiorlaan 1...

Отзывы: