MDR2400-SR, MDR5800-SR and Orion 5825-SR
Issue 10
Page 22
In ALL cases flashing red and orange LEDs imply historic alarm conditions (The alarm
can be cleared using the front panel button ‘position 1’ : see next section).
Flashing LED’s and yellow indicators (Orion NMS) may also be cleared by clicking on
the “Clear Alarms” button in the Orion NMS Main Radio Window.
2.3.4 Reset / Configuration Button
The functionality of the Reset Button is described below. These functions are used to
set up the radio. A paper clip or similar “probe” can be used to push the “reset /
configuration button”. The count value / LED count at which the button is released, will
be the "new" configuration / state of the IU.
The count value is determined by the different LEDs lighting up. ‘Position 1’ being RF
Link LED (Green), 2 being Payload LED (Green), 3 being System LED (Green), 4 being
RF Link LED (Orange), 5 being Payload LED (Orange) and 6 being System LED
(Orange) etc.
Reset button functions (according to "LED reset" number)
1. Clear Front Panel LEDs (and associated alarms in IU)
2. Clear Event Log in the Indoor Unit
3. Reset the Indoor Unit (
does not
reset the non-volatile memory storing the IU’s
configuration parameters)
4. Routed Configuration: Reset the IU configuration parameters that are stored in non-
volatile memory (BATTERY-BACKED STATIC RAM) and configure as a ‘Far Side
IU’ : i.e. for a ROUTED IP configuration, set the Ethernet IP address as 10.11.1.2,
Element Manager IP address to 10.12.1.2
5. Routed Configuration: Reset the IU configuration parameters that are stored in non-
volatile memory and configure as a ‘Near Side IU’ : i.e. for a ROUTED IP
configuration set the Ethernet IP address as 10.2.1.2, Element Manager IP address
to 10.13.1.2
6. Routed Configuration: If you are not sure how the IU is configured (NEAR or FAR
side IU), reset it AS IS i.e. reset the ‘Near Side IU’ or ‘Far Side IU’ configuration
parameters depending on how the IU is currently configured.
7. Bridged Configuration: Reset the IU configuration parameters that are stored in non-
volatile memory (BATTERY-BACKED STATIC RAM) and configure as a ‘Far Side
IU’ For a BRIDGED IP configuration, see Appendix C of this document for a
description of the default IP addresses.
8. Bridged Configuration: Reset the IU configuration parameters that are stored in non-
volatile memory and configure as a ‘Near Side IU’. For a BRIDGED IP
configuration, see Appendix C of this document for a description of the default IP
addresses.
9, 10, 11 RESERVED
12. Set up Indoor Unit with E1 tributaries.
13. Set up Indoor Unit with T1 tributaries.
14. Deactivate buttons 4 onwards.
15. Toggle SNMP and FTP Servers ON/OFF (V3.00+ firmware)
16. DHCP ON (V3.00+ firmware)
17. DHCP OFF (V3.00+ firmware)
18. Ethernet MAC learning enabled via front panel
19. Transparent ethernet mode enabled via front panel
Содержание MDR2400-SR
Страница 13: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 13...
Страница 41: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 41 This page is left blank intentionally...
Страница 67: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 67...
Страница 68: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 68...
Страница 70: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 70...
Страница 73: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 73...
Страница 74: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 74...
Страница 75: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 75...
Страница 79: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 79...
Страница 128: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 128...
Страница 131: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 131 R reset button 22 W web links 113 www See web links...