MDR2400-SR, MDR5800-SR and Orion 5825-SR
Issue 10
Page 109
4 Appendix: MDR5800 hardware VERSION 1, 2.x
DIFFERENCES, COMPATIBILITY SUMMARY
Version 1 hardware (Indoor and Outdoor Units) is
incompatible
with Version 2.x
hardware.
•
The Indoor Unit /Outdoor Unit Twisted Pair Data Interconnection for Version
2 hardware uses 2 twisted pair cables to convey payload and Outdoor Unit
control signals whereas Version 1 hardware uses 4 twisted pair cables.
Notes :
Version 2.x firmware (can be uploaded into the Indoor Unit using the NMS’s
Maintenance option) that can be used in Version 1.x hardware must be obtained
from the product manufacturer. The file is
not
the same file that is used with
Version 2.x hardware.
Updated RSSI and Power control functionality have been added to Version 2.x
hardware and firmware.
Version 2.x firmware has
1. FTP upload functionality (needs to be activated via the MIB)
2. IP Bridging functionality (half and full duplex – selectable via the MIB).
Appropriate IU hardware must be used.
3. Band Plan C
4. Refer to the MIB section of this manual and look for the † symbol to see
what MIB-related functionality is in place/activated/planned for Version 2.x +
firmware.
5. Functional RF Loopback built-in test feature.
6. Ethernet packet error monitoring and buffer monitoring added to MIB
7. E1 CRC4 payload monitoring added to MIB (only applicable for a single
tributary)
8. Indoor Unit PCB hardware revision added to MIB
9. Periodic reporting of RF Link packet errors (adjustable in time, defaulted to
10 minutes) added to MIB.
Version 2.x NMS has
1. Ability to allow the user to connect to the Indoor Unit using PPP (via a serial
cable interface to the IU’s front panel Element Manager RS232 port) or via
Ethernet (via the front panel RJ45 connector: 10BaseT).
2. Graphical Spectrum Analyzer display
By default, firmware provided for the Indoor Units does not provide a secure login
feature (thereby limiting a user’s ability to ‘set’ MIB variables). Suitably adapted
firmware versions (dependent on hardware version) need to be requested from the
product manufacturer to allow activation of this feature.
Содержание MDR2400-SR
Страница 13: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 13...
Страница 41: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 41 This page is left blank intentionally...
Страница 67: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 67...
Страница 68: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 68...
Страница 70: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 70...
Страница 73: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 73...
Страница 74: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 74...
Страница 75: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 75...
Страница 79: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 79...
Страница 128: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 128...
Страница 131: ...MDR2400 SR MDR5800 SR and Orion 5825 SR Issue 10 Page 131 R reset button 22 W web links 113 www See web links...