EasyReach
User Manual
TROUBLESHOOTING
1H90941
19
Bench Testing
To aid system commissioning or to check the integrity of the equipment, the
Plessey
EasyReach
link may be bench tested by bypassing the antennas, as
shown in Figure 6.
Units may only be connected with an attenuator exceeding 50 dB in the path
between antenna ports.
CAUTION
Do not connect the antenna ports of two units directly together. Damage of
both units will result.
Figure 6
Bench Testing Arrangement (E1 Version)
110/240
VAC
or
20 to 60
VDC
DATA
IN
DATA
OUT
TERMINAL
MANAGEMENT
ALARM
ANTENNA
TERMINAL
POWER
110/240
VAC
or
20 to 60
VDC
DATA
IN
DATA
OUT
TERMINAL MANAGEMENT
ALARM
ANTENNA
TERMINAL
POWER
E1 DATA
RF ATTENUATOR
(50 dB MINIMUM)
ANTENNA FEEDER CABLE
Figure 7
Bench Testing Arrangement (T1 Version)
110/240
VAC
or
20 to 60
VDC
T1 DATA
TERMINAL MANAGEMEN
ALARM
ANTENNA
TERMINAL
POWER
110/240
VAC
or
20 to 60
VDC
T1 DATA
TERMINAL MANAGEMEN
ALARM
ANTENNA
TERMINAL
POWER
T1 DATA
RF AATTENUATOR
(50 dB MINIMUM)
ANTENNA FEEDER