EasyReach
User Manual
TROUBLESHOOTING
1H90941
17
Status Indicators
POWER LED Not Green
If the POWER LED is not green when the
SUPPLY
switch is on, the problem
may be one of the following:
•
The power supply to the unit has failed or there is a faulty connection.
Check the connections. Check the unit power supply. For DC versions of
EasyReach
, it should be between 20 and 60 volts DC. Ensure that the
polarisation is correct. For AC versions of
EasyReach
, it should be
between 110 and 250 volts AC.
•
The power fuse on the
EasyReach
board has blown, caused by:
Incorrect fuse rating. Check the rating and replace.
Fault in the
EasyReach
power supply.
FAIL LED is Red
This indicates a power or system fail:
•
Internal fault with the unit. Return for repair.
DATA LED is Red
The DATA LED is red when:
•
The
EasyReach
unit cannot detect data on the
DATA
port.
•
The
EasyReach
unit detects bipolar code violations on the
DATA
port.
Check the
DATA
connection and verify the integrity of the incoming E1 or T1
data.
RF SIGNAL LED is Red
The RF SIGNAL is red when the
EasyReach
unit is not receiving an RF signal of
sufficient strength from the other end of the link to acquire reliable data.
Firstly, check that the unit at the other end of the link is switched on.
If the RF SIGNAL indicator at the other end of the link is also red or intermittently
red, then the problem may be one of the following:
•
Incorrect use of
EasyReach
frequency variants. Refer to page 11 for
details of the available frequency options.
•
One of the
EasyReach
units has been configured incorrectly.
Restart both units, and ensure that both radio units have the same