Pleiger Control Loop
Manual version 2018-03
Abbreviation Description
EHS_D
standard double acting valve
EHS_DK
double acting valve with analog feedback
EHS_SO
single acting valve, spring open
EHS_SC
single acting valve, spring close
EHS_SOK
single acting valve, spring open with analog feedback
EHS_SCK
single acting valve, spring close with analog feedback
EHS_SCO
single acting valve, spring close with mechanical override
EHS_SOO
single acting valve, spring open with mechanical override
MOV
standard motor valve
QC_SC
single acting valve, spring close, with external quick close circuit
QC_SO
single acting valve, spring open, with external quick open circuit
EHS_SCH
single acting valve, spring close with electro-hydraulic override
EHS_DQ
double acting valve with separated hydraulic unit
EHS_SCQ
single acting valve with separated hydraulic unit, requires additional relay
QC_SCQ
single acting valve with separated hydraulic unit, requires additional relay
external coil supply for quick closing function required
EHS_DEx
double acting valve for use in hazardous area, requires additional CM-ExE module
EHS_DKEx
double acting valve for use in hazardous area with analog feedback, requires addi-
tional CM-ExE module
EHS_DOS
double acting valve, opening in two steps (time adjustable by auxiliary parameters)
EHS_SC_Step single acting valve, spring close with step close function
EHS_SCO2 single acting valve, spring close with hydraulic override
CAUTION
Malfunction / Damage / dangerous situation
Take care to set up the right actuator type fitting to the installed hardware! A miss-
match could stress the actuator with wrong supply and signals. The actuator and / or
the PCL-VCI could be damaged!
10.3.9 Modify the Auxiliary parameter
Aux parameter editor pages are available for all actuator types. See the table Table 10-1: Aux param-
eters overview for actuator types (EHS-Types)
” on the next page whether parameters are required.
No. EHS-Type
Description
Aux 1
Aux 2
1 EHS_D
standard open / close
<6
<6
close / step-open
>= 6 [s]
<6
Figure 10-28: Aux 1 parameter editor page
Figure 10-29: Aux 2 parameter editor page