5
INSPECT APPLIANCE & COMPONENTS AND
PRE-USE CHECK LIST
1.
Place the appliance in a location near the final
installation area and follow the procedures below:
2.
Open the appliance and remove all the parts and
articles packed inside the Component Pack.
Inspect all the parts and glass for shipping damage.
Contact your dealer if any irregularities are noticed.
3.
All safety warnings have been read and followed.
4.
This Owner’s Manual has been read.
5.
Floor protection requirements have been met.
6.
Venting is properly installed.
7.
The proper clearances from the appliance and
chimney to combustible materials have been met.
8.
The masonry chimney is inspected by a professional
and is clean, or the factory built metal chimney is
installed according to manufacturer’s instructions
and clearances.
9.
The chimney meets the required minimum height.
10.
All labels have been removed from the glass door.
11.
A power outlet is available nearby if installing
optional blower assembly.
VENTING SYSTEMS
The venting system consists of a chimney connector
(also known as stove pipe) and a chimney. These get
extremely hot during use. Temperatures inside the
chimney may exceed 2000°F (1100°C) in the event of
a creosote fire. To protect against the possibility of a
house fire, the chimney connector and chimney
must
be properly installed and maintained.
An approved
thimble must be used when a connection is made
through a combustible wall to a chimney. A chimney
support package must be used when a connection is
made through the ceiling to a prefabricated chimney.
These accessories are
absolutely necessary
to provide
safe clearances to combustible wall and ceiling material.
Follow venting manufacturer’s clearances when installing
venting system.
TOOLS AND SUPPLIES NEEDED
Before beginning the installation be sure that the follow-
ing tools and building supplies are available.
Reciprocating saw
Framing Material
Pliers
Hi-Temp Caulking Material
Hammer
Gloves
Phillips Head Screwdriver Framing Square
Flat Blade Screwdriver
Electric Drill & Bits (1/4”)
Plumb Line
Safety Glasses
Level
1/2 in. - /4 in. length, #6 or
Tape Measure
#8 self drilling screws (need
per pipe section connection)
WARNING
Asphyxiation Risk.
• Do NOT connect this unit to a chimney flue servicing
another appliance.
• Do NOT connect to any air distributon duct or system.
May allow flue gases to enter the house.
WARNING
Fire Risk.
Inspect appliance and components for damage.
Damaged parts may impair safe operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.