background image

Platypus Fire Pty Ltd makers of the 

The Sensible Bushfire

Protection System

Refer to section 2 of this guide for information about bracket spacing and sprinkler pressure, flow and spacing.
All diagrams are to be used as guides only.

7

Platypus Fire Pty Ltd (ACN 159 992 355) 

Platypus Sprinkler 

Product Warranty 

1. DEFINITIONS

1.1 In this Warranty the following definitions apply: 

Date of Purchase 

has the meaning set out in clause 3.2. 

Platypus 

means Platypus Fire Pty Ltd (ACN 159 992 355) of PO Box 466, Trafalgar VIC 3824 

Australia. 

Purchaser 

means the purchaser of the Platypus Sprinkler. 

Sprinkler 

means the Platypus Sprinkler including the following sprinkler models: 

a) Model PFSS25;
b) Model PFSS32;
c) Model PFSS40.

Return of Goods Authorisation Number 

means the number allocated by Platypus to a claim for 

the return of the Sprinkler. 

Term

 has the meaning set out in clause 3.1. 

Warranty 

means this Platypus Sprinkler Product Warranty. 

2. GENERAL

2.1 Our products come with guarantees that cannot be excluded under the Australia Consumer 

Law. You are entitled to a replacement or refund for a major failure and compensation for 
any other reasonably foreseeable loss or damage.  You are also entitled to have the goods 
repaired or replaced if the goods fail to be of acceptable quality and the failure does not 
amount to a major failure. 

Product Warranty

Содержание PFSS25

Страница 1: ...3 Sprinkler Assembly and Cleaning Instructions 4 Flow Control Insert Specifications 5 System Maintenance 6 Warranty 7 10 PLATYPUS CONTROLLER PLATYPUS CONTROLLER PLATYPUS CONTROLLER Platypus Fire Pty L...

Страница 2: ...35o Please read supplied mounting diagrams and how to information to ensure the sprinkler is installed correctly This product is supported by a 12 month warranty This illustration below shows the reco...

Страница 3: ...d as guides only 3 Overall height of the sprinkler is 81mm A Width at the widest point is 51mm B Weight is 85 grams Inlet 1 2 BSP thread Construction Sprinkler Head Glass reinforced nylon with flame r...

Страница 4: ...ts correctly onto flat edges on either side of the nozzle taking care not to leave any burrs as these may catch on the sprinkler head 2 Clean shaft bearing and nozzle using clean water DO NOT USE SOLV...

Страница 5: ...r flow through the flow control insert Length overall 17mm Outside diameter 15mm Flow rate 5 5lpm to suit 2 5mm nozzle or 9lpm to suit 3 2mm nozzle not available for 4 0mm nozzle Maximum working temp...

Страница 6: ...ters downpipes strainer basket Check operation of mains water top up Start pump check operation of system flush system with clean water if using pool water and or bore water etc Prepare discuss and or...

Страница 7: ...s Sprinkler Sprinkler means the Platypus Sprinkler including the following sprinkler models a Model PFSS25 b Model PFSS32 c Model PFSS40 Return of Goods Authorisation Number means the number allocated...

Страница 8: ...es to repair or replace at Platypus expense the Sprinkler purchased by the Purchaser in Australia directly from Platypus or from a Platypus authorised distributor if and when the product does not perf...

Страница 9: ...5 REPAIR OR REPLACEMENT 5 1 Sprinklers may either be repaired or replaced at Platypus discretion 5 2 If a Sprinkler is to be replaced it may be replaced by products of similar design to the Sprinkler...

Страница 10: ...ifications f to any replacement or repair of any lost parts or accessories g service of the Sprinkler while it is outside Australia h to any wear and tear if the Sprinkler is used for commercial indus...

Отзывы: