Installation: Selectable Features
Close Timer
Timer Feature when activated will close
the gate automatically of a set number of
seconds. This is adjustable from 3 to 60
seconds.
Leaf Delay
An Overlap Delay has been provided for
biparting gates that have an emblem
or maglock for example. It will provide
up to a 3 second delay on primary or
secondary operator.
Instant Reversing Sensor
The Obstruction Sensor needs to
be adjusted to compensate for the
installation and gate weight. The
overload adjustment is provided to set
the gate sensitivity.
a) If the gate reverses by itself or stops
in midcycle, it is too sensitive.
b) If the gate hits an object and does
not reverse or stop, it is not sensitive
enough.
c) Clockwise increases sensitivity,
counterclockwise decreases
sensitivity.
Test and adjust for proper
reversing pressure
(Note: When unit alarms, push “STOP” or
“RESET” button will clear the alarm)