background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

IG0263#04 

21.02.2020 

 

17 

 

Remove  the  battery  and  place  the  new  one  into  the  container. 

WARNING!

 

Remember  about  proper 

polarization of the battery. 

 

 

Screw the cover of the battery container. 

5.

 

TESTING

 

WARNING!!! 

NEVER TURN ON THE DEVICE IF THE CHARACTERISTIC SMELL OF GAS IS PERCEPTIBLE.

  

If you smell gas during the operation of the fireplace turn off the device immediately and cut off the gas supply from 

the gas cylinder by shutting its valve. 

5.1

 

Checking for gas leaks. 

 

Check if all connections are airtight. 

 

To  do  that  apply  all  connections  with  soapy  water  (or  water  with  another  foamy  substance)  or  with  a 

professional spray for leak detection. 

 

If air-bubbles are present that means the connection has a leak. 

 

Remove the leaks in the identified spaces. 

 

Check for leaks once again. 

 

After the inspection dry the inspected connections. 

 

The device may only be used again after all leaks are removed.  

 

If the problem happens again please contact the dealer. 

5.2

 

Checking the flame appearance. 

 

Burn the Gustav Gas on max flame height and check the appearance of the flame. 

 

The flame should evenly placed on the whole surface of the main burner. 

 

If visible gaps are present or there are substantial differences in flame height turn off the fireplace and after 

the device is cooled adjust the placement of decorative stones in such a way for them to be evenly placed on 

the whole surface of the main burner. 

 

WARNING!!!

 

Remember not to cover the protective basket which houses the ignitor and thermocouple, with 

stones. 

 

Turn on the fireplace and check the appearance of the flame once again. 

Содержание GUSTAV Gas

Страница 1: ...a Sp z o o www planikafires com IG0263 04 21 02 2020 1 INSTALLATION and USER S MANUAL GUSTAV Gas G30 G31 Propane Butane Propane H L D mm 1302 370 490 Manufactured by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland ...

Страница 2: ...7 3 4 Installation of the gas linkage 8 3 4 1 Connection and replacement of the gas cylinder 8 3 4 2 Adapter for the gas cylinder connection 10 3 4 3 Regulator replacement 11 4 USER S MANUAL 13 4 1 Start up of the device 13 4 2 Regulation of the flame size 15 4 3 Device shutdown 16 5 TESTING 17 5 1 Checking for gas leaks 17 5 2 Checking the flame appearance 17 6 MAINTENANCE AND UPKEEP 18 6 1 Testi...

Страница 3: ...ing the appliance In case of violent wind precautions must be taken against tilting of the appliance This appliance must be used and the gas cylinder stored in accordance with the regulations in force The Gustav fireplace should installed and controlled annually according to the below installation manual as well as enforced national and local laws regarding gas safety installation and use One need...

Страница 4: ...eeds to be turned off If the Gustav Gas is not in use for a longer period of time e g winter time we advise you to store it inside Corrosion of the coating of the base of Gustav Gas is a natural process resulting from the characteristics of the Corten steel which the fireplace is made of It is an additional protective layer of the appliance against the negative influence of unfavorable weather con...

Страница 5: ...ng leak Always use a pressure regulator between the gas bottle and the device Replace the pressure regulator every 5 years The allowed pressures are 30mbar 37mbar recommended 50 mbar Use only regulators complying with the European EN16129 Norm Use only approved and certified gas connection linkage Replace the linkage every 2 years Check the flexible hose at least once per month and each time the c...

Страница 6: ...rom the burner reservoir and place them away from it Check the completeness of the elements with the contents list Make sure that the device nor its elements weren t damaged during the transportation if they were notify the supplier Place Gustav Gas on a flat paved surface outside of the building preferably on the place of final installation Leave sufficient space on the side of the appliance wher...

Страница 7: ...ective basket of the ignition unit Photo 2 3 3 Gas cylinder montage The gas linkage attached to the device allows to place the gas bottle maximally 2 meters away from the connected control panel during it replacement During operation the gas cylinder is hidden inside the device behind doors equipped with magnetic locking system ...

Страница 8: ...the regulator as well as the gas linkage and if necessary for instance broken cut scratched linkage replace the components for new ones according to national standards and norms The Gustav Gas fireplace can use metal or steel bottles or composite bottles filled with propane butane gas or propane gas This device features a twist on regulator with current pressure of 37mbar It can be replaced into a...

Страница 9: ...ing knob left thread Do not allow the gas bottle connectors to be fastened too tightly 3 Place the quick release regulator on the valve and press it down hard If the switch is correctly turned off you will hear a characteristic click 5 When the gas flow is required turn the valve of the bottle counter clockwise 4 To let the gas flow in turn the switch into the ON position or into the flame image P...

Страница 10: ...the regulator or the connecting nut with the use of a wrench or a connecting knob 3 Take off the quick release regulator by pressing the switch horizontally and simultaneously pulling the whole regulator upwards 5 REPLACE the linkage closer or cap on the empty or partially full bottle if it s not being used 4 REPLACE the tightening cap on an empty or partially full bottle if it s not being used 3 ...

Страница 11: ... 8x1 14 LH 3 4 3 Regulator replacement 1 You always need to use a pressure regulator between the gas bottle and the device Replace the pressure regulator every 5 years Allowed pressures 30 mbar 37 mbar recommended 50 mbar Use only the redactors that comply with the EN16129 European Norm 2 Turn off the Gustav Gas the OFF position The main burner and the pilot burner need to be turned off 3 Disconne...

Страница 12: ...ARNING In the event of visible damage on the clamp replace it for a new one Gustav Gas is equipped with the anti tilt valve which shuts the device down in case if the fireplace is tilted or collapsed The valve automatically cuts off the gas supply to the controller and this extinguishes the flame WARNING make sure the anti tilt valve is always installed in upward position ...

Страница 13: ...t pilot flame The flame height of the main burner may be appropriately regulated with by turning the knob Next to the know is placed elective ignition button powered by AA battery The control panel is placed behind the door of the gas cylinder compartment Photo 3 Photo 3 4 1 Start up of the device Make sure that the knob is placed in OFF position all the way clockwise Photo 4 Photo 4 ...

Страница 14: ... have replaced and installed a new LPG gas cylinder When the flame is ignited keep holding the knob for around 5 seconds until the thermo couple which will keep the main valve in an open position warms up You may now release the knob If however the flame is extinguished repeat the process once again until a stable flame is achieved WARNING After 2 3 unsuccessful attempts terminate and check the co...

Страница 15: ...me size When the flame is burning the desired height of the flame may be adjusted and regulated by turning the knob clockwise or counter clockwise To achieve a higher flame turn the know counter clockwise to Hi position To achieve a lower flame turn the knob clockwise to Lo position Photo 7 Photo 7 ...

Страница 16: ...e flame on burner will be turned off Photo 8 Additionally close also the valve on the gas cylinder 4 4 Replacing the battery If the battery is inserted incorrectly the electronic ignitor may be irreparably damaged Only replace the battery when the appliance has been completely switched off The battery is placed in the container located on the control pane next to the flame regulation knob Unscrew ...

Страница 17: ... present that means the connection has a leak Remove the leaks in the identified spaces Check for leaks once again After the inspection dry the inspected connections The device may only be used again after all leaks are removed If the problem happens again please contact the dealer 5 2 Checking the flame appearance Burn the Gustav Gas on max flame height and check the appearance of the flame The f...

Страница 18: ...ace the glass screen for a new one To conduct this contact your dealer Gas linkage and pressure regulator in case their expiry date is invalid replace these ancillaries for new ones If you encountered problems with the regulator gas linkage burner or regulation valves do not try to fix these parts Contact a sales person an authorised service or an importer in order to acquire spare parts To ensure...

Страница 19: ...ed 7 Pressure regulator link is loose 1 Replace Gas Cylinder 2 Connect the igniter linkage 3 Replace igniter 4 Realign electrode and clear any surrounding debris from area 5 Unmount burner clean the nozzle 6 Straighten the linkage Keep the linkage away from the housing 7 Tighten the link Check for leaks Igniter Not Working 1 Ignitor wire not connected 2 Electrode misaligned on pilot burner 3 Ignit...

Страница 20: ... mm 1 1 1 1 1 1 Gas consumption kg h 0 28 0 32 0 35 0 28 0 32 0 35 0 27 0 28 0 32 Nominal Heat Input Hi kW 3 7 4 1 4 8 4 2 4 7 5 5 4 1 4 2 4 1 Nominal Heat Input Hs kW 4 0 4 4 5 2 4 6 5 2 6 0 4 5 4 6 4 4 Safety device Thermocouple Gas control valve BS190 Flexible hose 2 m Ø9mm 9 MANUFACTURER S CONTACT DETAILS Company Name Planika Sp z o o Address Bydgoska 38 86 061 Brzoza Poland Telephone 48 52 36...