background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

 

 

 

 

 

C.

 

Flame size regulation 

The FLA 2 model E can operate in two modes: Normal and ECO. The device always starts with a standard flame size. 

The device has the adjustable flame size during operation.  

In order to reduce the height of the flame, press the ECO button. You will hear two beeps and the ECO button will be 

highlighted. The unit is now operating in ECO mode. 

To  return  to  the  normal  height  of  the  flame,  press  the  ECO  button,  you  will  hear  one  beep  and  the  ECO  button 

backlight turns off. The device is now in normal mode. 

ATTENTION!

 It might take a few moments for the flame to adjust. 

ATTENTION!

 The device switches to ECO mode by itself when there is a danger of over-temperature of the device. 

D.

 

Device extinguishing 

Press the 

START/STOP

 button on the control panel. You will hear two beeps and the red indicator              will start to 

blink. 

The blinking red indicator means that the device is too hot to be restarted. When the device cools the message will 
disappear, and depending on the amount of the fuel in the tank, either the green indicator will flash and indicate the 
readiness for operation or the blue indicator will indicate the lack of the fuel. 

E.

 

Subsequent start up 

If on the control panel flashes the blue FUEL indicator, start to run the product from the point B.2. 

If on the control panel flashes the green READY indicator, you can: 

 

start to run the product from the point B.3. 

 

open the filler bolt: 

- the blue indicator blinks and a beep sounds intermittently - the tank is full and it is not allowed to pour any 
more fuel! Close the fuel filler bolt and proceed in accordance with section B.3. 

- the blue indicators blinks - you can refuel (see section B.2) and turn on the device (see section B.3) or close 
the fuel filler bolt and activate the device by following the point B.3. 

 

F.

 

Information and warning alert 

In order to increase safety, the FLA 2 model E is equipped with an electronic system to keep the operation safe. In the 
case of a dangerous situation, the device immediately triggers alarms. 

 
LEGEND: 

HOT

HOT

HOT

The indicator is off 

The indicator flashes 

The indicator is blinking 

HOT

Содержание FLA 2 E#4

Страница 1: ...USER S MANUAL FLA 2 model E 4 PF 0855 0017 000 PF 0855 0018 000 Manufactured by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland Edition i1108 00 as of 25 04 2016 Serial number greater than P4024 16 ...

Страница 2: ... NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L TABLE OF CONTENTS I General information 3 II Fuel 3 III Safety 3 IV Operation 4 Operating elements 5 Initial start up of the device 5 Flame size regulation 8 Device extinguishing 8 Subsequent start up 8 Information and warning alert 8 V Cleaning and maintenance 10 VI Disposal and recycling 10 VII Service 10 ...

Страница 3: ...ess dizziness Warning markings R 11 Highly flammable liquid Operational notes S 2 Store beyond children s reach S 7 Keep container tightly closed S 16 Keep away from sources of ignition No smoking S 46 In case of ingestion immediately seek medical advice show the package or label This mark stands for information which one needs to acquaint with This mark stands for warnings which one needs to acqu...

Страница 4: ...e device while it is switched on Do not operate near the fuel filler while the device is switched on Do not operate with the components contained within the flame tray under the threat of burns or damage to the device Do not move the device while it is switched on The device can be moved only after the complete combustion of the fuel when it is disconnected from power supply and when all its eleme...

Страница 5: ...nel v START STOP READY FUEL Planika HOT ERROR N E W S E N S O F F I R E PAT PEND ECO B Initial start up of the device 1 On the control panel the blue light flashes it indicates the lack of fuel in the tank Please refuel 2 Refuelling For refuelling please use the automatic fuel pump provided with the FLA 2 model E Service USB input hidden under a cap Starts the device from standby mode or switches ...

Страница 6: ...tor to the matching socket underneath the filler flap Properly attached fuel connector should make a click sound Plug the automatic fuel pump power cord to the matching socket underneath the fuel filler flap Both should be placed firmly in their place 2 3 Place the stiff tube in the external fuel container from which the fuel will be pumped out into the FLA 2 model E s fuel tank 2 4 To start the a...

Страница 7: ...the LED lights on FLA 2 model E will indicate FLA 2 model E is ready to use fuel level is too low Please refuel starting from point 2 1 While refueling please take the following precautions During pouring be careful not to spill out the fuel If the fuel is spilled error message READY FUEL HOT may be displayed Go to step F and follow the guidance provided in the table If the spillage is excessive t...

Страница 8: ...e device cools the message will disappear and depending on the amount of the fuel in the tank either the green indicator will flash and indicate the readiness for operation or the blue indicator will indicate the lack of the fuel E Subsequent start up If on the control panel flashes the blue FUEL indicator start to run the product from the point B 2 If on the control panel flashes the green READY ...

Страница 9: ...ill cease automatically Disconnect the automatic pump Wait at least 1 hour to evaporate the remaining moisture and then close the fuel filler bolt Hold the ECO button for about 5 seconds If the alarm message reappears wait a little bit longer until the rest of the moisture evaporates If the message reappears contact your service provider the acceptable device operation temperature has been exceede...

Страница 10: ...uation where it will be necessary to clean elements not normally available The manufacturer is not liable for damage resulting from improper operation non manual self dismantling attempts to modify using other liquids than those recommended in point II Fuel VI Disposal and recycling The product is equipped with parts made of aluminium steel plastics and electronics If you need to dispose of the de...

Отзывы: