Planex FMX-24NZ Скачать руководство пользователя страница 86

- 86 - 

Delete filter MAC address 

 

Actions->

 

1.

 

Press 

<Delete> 

key to delete a filter MAC address. 

 

2.

 

Choose the MAC address that you want to delete and then press enter. 

 

3.

 

When pressing 

<Enter> 

once will complete deletion on delete mode.   

 

 

 

Содержание FMX-24NZ

Страница 1: ... 1 ...

Страница 2: ...TATISTICS 16 2 4 SHOW MAC TABLE 18 2 5 ADMINISTRATOR 19 2 5 1 IP Address Subnet Mask Gateway 19 2 5 2 Switch Setting 20 2 5 2 1 Advanced 20 2 5 2 2 Misc Config 22 2 5 3 Console Port Information 23 2 5 4 Port Controls 23 2 5 5 Trunking 26 2 5 5 1 Aggregator setting 26 2 5 5 2 Aggregator Information 27 2 5 5 3 State Activity 28 2 5 6 IGMP and MAC Filter 29 2 5 6 1 IGMP Snooping 29 2 5 6 2 Static MAC...

Страница 3: ...VLAN Group 62 4 2 3 3 Edit Delete a VLAN Group 64 4 2 3 4 Groups Sorted Mode 65 4 2 4 Misc Configuration 66 4 2 4 1 Ping 67 4 2 4 2 MAC Age Interval 67 4 2 4 3 Broadcast Storm Filtering 68 4 2 4 4 Max bridge transmit delay bound 69 4 2 4 5 Port Security 69 4 2 4 5 Collisions Retry Forever 70 4 2 4 6 Hash Algorithm 71 4 2 4 7 IFG Compensation 71 4 2 5 Administration Configuration 73 4 2 5 1 Change ...

Страница 4: ... 5 2 State Activity 101 4 3 5 3 LACP Status 102 4 3 6 802 1x Protocol 104 4 3 6 1 802 1x Enable 104 4 3 6 2 802 1x System Configuration 106 4 3 6 3 802 1x PerPort Configuration 107 4 3 6 4 802 1x Misc Configuration 108 4 4 STATUS AND COUNTERS 109 4 4 1 Port Status 109 4 4 2 Port Counters 110 4 4 3 System Information 111 4 5 REBOOT SWITCH 112 4 5 1 Default 112 4 5 2 Restart 112 4 6 TFTPUPDATE FIRMW...

Страница 5: ...ht line or cross line issues FMX 24NZ switch provides a convenient way to operate layer 2 management through the browser The User friendly drop down menu allows the user to easily learn control and monitor It supports not only traditional SNMP function but also RMON 1 2 3 9 groups for advanced network analysis A new management tool called Single IP is implemented here to provide the administrator ...

Страница 6: ...nector z Make sure that there is proper heat dissipation form and adequate ventilation around the Switch Desktop or Shelf Installation When installing the Switch on the desktop of shelf the rubber feet included with the device should first be attached Attach these cushioning feet on the bottom at each corner of the device Allow adequate space for ventilation between the device and the objects arou...

Страница 7: ...ED indicators should respond as fallows z All LED indicators will momentarily blink This blinking of the LED indicators represents a reset of the system z The power LED indicator will blink while the Switch loads onboard software and performs a self test After approximately 20 seconds the LED will light again to indicate the switch is in a ready state z The Speed Link Activity LED indicator may re...

Страница 8: ... or responded correctly as you wish 1 3 1 out of band Terminal mode Management First turn on your PC and execute with terminal mode program such as if you are in Microsoft Window environment you may choose super terminal from programs that are listed for communication Then follow the steps below Step 1 Set Hyper Terminal parameters on your PC Bits Rate per second 9600 Parity None Data Bits 8 Stop ...

Страница 9: ...ration described in chapter 4 while the IP Address and Subnet Mask of PC can be found in your PC system Second in general within a network the members in the same network domain must have the same Subnet IP unless there are routers between them or members in the same network domain can t talk to each others so make sure the communication members in the same domain must have different IPAddresses a...

Страница 10: ... IP configuration value used for switch from your network manager Get an IP Address for your switch get IP Subnet Mask and get default gateway IP address if needed from your network manager Step 3 Modify the IP configuration value within the switch to match the rule In the step 3 you must use the data that get from step 2 to modify the default value within the switch to achieve this use terminal m...

Страница 11: ...ation before executing the Telnet program Again after proper setting to the switch save the setting and connect your Ethernet cable from your PC to any port of the Ethernet Switch then you can simply typing as following at the command line to access the switch Telnet IP_Address_of_Switch The following dialogue below appears Type user name and password to get further service To find out more operat...

Страница 12: ... switch Each RJ 45 of 10 100M is with two LEDs built in on its upper corner left one indicates link status and activity while the right one indicates the speed information Each RJ 45 of 10 100 1000M for gigabit module optional is somewhat different Upper yellow LED indicates for 10M LINK middle green LED indicates for 100M LINK but for 1000M or Gigabit both upper and middle LEDs are lit when gigab...

Страница 13: ... type MAC Address The unique hardware address assigned by manufacturer default Firmware Version Display the switch s firmware version ASIC Version Display the switch s ASIC version On the top of web page there is a link status from image of front panel every port will be with a connector icon if this port is really linked with others you also may click the function that listed at left Below is the...

Страница 14: ...gotiation mode auto force Nway force 4 Speed status Display 1000Mbps or 100Mbps or 10Mbps speed port 1 24 are 10 100Mbps Port 25 26 are 10 100 1000Mbps 5 Duplex status Display full duplex or half duplex mode 6 Flow Control Full Display the flow control is enabled or disabled in full mode Half Display the backpressure is enabled or disabled in half mode 7 Rate Control Display the rate control setti...

Страница 15: ...he state of user setting 10 Actual Display the negotiation result 2 2 1 single port counter and status User can also click the any port directly on the front panel of Home Page to get single port Status which is shown below ...

Страница 16: ...smitting abort packets of collision and drop packets The following two pages provide the statistics of RMON 1 2 3 9 groups The first part collects the information about packets of frame size within ranges of 64 65 127 128 255 256 511 512 1023 and 1024 1518 bytes the total received packets and the total receives bytes The second part collects the information about drop events broadcast packets mult...

Страница 17: ... 17 ...

Страница 18: ...tton will browse previous 50 or next 50 items The Top button will re list the table from the first MAC A sorting function is implemented here Clicking header on the top of table will bring a new sorted list of current content in the order of its title For instance clicking the MAC on the top of table will refresh the table by the index of MAC ...

Страница 19: ...nformation Port Configuration Trunking IGMP and MAC Filter VLAN Configuration Spanning Tree Port Mirror SNMP Trap Manager Security Manager 802 1x Configuration Ping 2 5 1 IPAddress Subnet Mask Gateway User can modify the switch IP Settings by filling with the new value then clicks apply button to confirm save his setting then he must reboot switch then new IP configuration value will be activated ...

Страница 20: ...fault is 300 seconds Max bridge transit delay bound control Limit the packets queuing time in switch If enable the packets queued exceed will be drop These valid values are 1sec 2 sec and 4 sec and off Default is 1 seconds NOTE Make sure of Max bridge transit delay bound control is enabled before enable Delay Bound because Enable Delay Bound must be work under Max bridge transit delay bound contro...

Страница 21: ... High before Low The high priority packets sent before low priority packets WRR Weighted Round Robin Select the preference given to packets in the switch s high priority queue These options represent the number of high priority packets sent before one low priority packet is sent For example 5 High 2 Low means that the switch sends 5 high priority packets before sending 2 low priority packets Enabl...

Страница 22: ... packet will be dropped if collision still happen Enable In half duplex if happen collision will retry forever Hash Algorithm Choose algorithms CRC Hash or DirectMap to maintain MAC address table IFG Compensation Enable or disable inter frame gap IFG compensation 802 1x Protocol Enable or disable 802 1x protocol ...

Страница 23: ...face to communicate with Serial Port User can use windows HyperTerminal program to link the switch Connect To Configure Bits per seconds 9600 Data bits 8 Parity none Stop Bits 1 Flow control none 2 5 4 Port Controls User may modify or change mode operation in this page ...

Страница 24: ...ressure is enable or disable in half mode 6 Rate Control port1 port 24 supports by port ingress and egress rate control For example assume port 1 is 10Mbps users can set its effective egress rate at 1Mbps and ingress rate at 500Kbps Device will perform flow control or backpressure to confine the ingress rate to meet the specified rate Ingress Type the port effective ingress rate The valid range is...

Страница 25: ...g packets with SMAC already existing in the address table can be forwarded normally User can disable the port from learning any new MAC addresses then use the static MAC addresses screen to define a list of MAC addresses that can use the secure port Enter the settings then click Apply button to change on this page ...

Страница 26: ...e ports into a single dedicated connection This feature can expand bandwidth to a device on the network LACP operation requires full duplex mode more detail information refers to IEEE 802 3ad 2 5 5 1 Aggregator setting 1 System Priority A value used to identify the active LACP The switch with the lowest value has the highest priority and is selected as the active LACP Valid value is 1 65535 2 Grou...

Страница 27: ...e as same as the group member ports 5 Select the ports to join the trunking group Allow max four ports can be aggregated at the same time 6 If LACP enable you can configure LACP Active Passive status in each port on State Activity page 7 Click Apply 2 5 5 2 Aggregator Information When you are setting LACP aggregator you can see relation information in here 1 This page is no group active LACP don t...

Страница 28: ...otocol packets from the opposite device 1 A link that has either two active LACP ports or one active port can perform dynamic LACP trunking A link has two N A LACP ports will not perform dynamic LACP trunking because both ports are waiting for and LACP protocol packet from the opposite device 2 If you are active LACP s actor when you are select trunking port the active status will be created autom...

Страница 29: ... members switches router or other network devices of group support IGMP With IGMP enable the member ports will detect IGMP queries report packets and manage the IP multicast traffic through the switch IGMP have three fundamental types of message as follows Message Description Query A message sent from the queries IGMP router or switch asking for a response from each host belonging multicast group ...

Страница 30: ...tatic MAC Address 2 In the MAC address box enter the MAC address to and from which the port should permanently forward traffic regardless of the device s network activity 3 In the Port Number box enter a port number 4 If tag based IEEE 802 1Q VLANs are set up on the switch static addresses are associated with individual VLANs Type the VID tag based VLANs to associate with the MAC address 5 Click t...

Страница 31: ... based on the destination addresses 1 In the MAC Address box enter the MAC address that wants to filter 2 If tag based 802 1Q VLAN are set up on the switch in the VLAN ID box type the VID to associate with the MAC address 3 Click the Add 4 Choose the MAC address that you want to delete and then click the Delete ...

Страница 32: ...p of network devices to another Layer 2 switch However all the network devices are still plug into the same switch physically The FMX 24NZ switch supports port based 802 1Q tagged based and protocol base VLAN in web management page In the default configuration VLAN support is disabling Support Port based VLAN Packets can only be broadcast among members of the same VLAN group Note all unselected po...

Страница 33: ... to send packets to different VLANs it itself has to be either capable of tagging packets it sends with VLAN tags or attached to a VLAN aware bridge that is capable of classifying and tagging the packet with different VLAN ID based on not only default PVID but also other information about the packet such as the protocol FMX 24NZ switch will support protocol based VLAN classification by means of bo...

Страница 34: ...select the members for the new VLAN 3 Click Apply 4 If there are many groups that over the limit of one page you can click the Next Page to view other VLAN groups NOTE If the trunk groups exist you can see it ex TRK1 TRK2 in select menu of ports and you can configure it is the member of the VLAN or not ...

Страница 35: ...to default VLAN VID is 1 The default VLAN can t be deleted GVRP GARP Generic Attribute Registration Protocol VLAN Registration Protocol GVRP allows automatic VLAN configuration between the switch and nodes If the switch is connected to a device with GVRP enabled you can send a GVRP request using the VID of a VLAN defined on the switch the switch will automatically add that device to the existing V...

Страница 36: ...d Protocol based VLAN classification User can combine the field Protocol Vlan and the field of the port number to form a new VLAN group NOTE IEEE 802 1v provides user to classify the packet through untagged port There are two possible strategies of the 802 1v supporting Port based VLAN and Port and Protocol based VLAN We can support both Port based VLAN and Port and Protocol based VLAN with our pr...

Страница 37: ...ou can see it in here ex TRK1 TRK2 and you can configure it is the member of the VLAN or not 6 Click Next Then you can view the page as follow 7 Uses this page to set the outgoing frames are VLAN Tagged frames or no Then click Apply Tag outgoing frames with VLAN Tagged Untag outgoing frames without VLAN Tagged ...

Страница 38: ...g FMX 24NZ switch each port allows user to set one PVID the range is 1 255 default PVID is 1 The PVID must as same as the VLAN ID that the port belong to VLAN group or the untagged traffic will be dropped Ingress Filtering Ingress filtering lets frames belonging to a specific VLAN to be forwarded if the port belongs to that VLAN FMX 24NZ switch has two ingress filtering rule as follows Ingress Fil...

Страница 39: ...wo nodes on the network You can enable Spanning Tree Protocol on web management s switch setting advanced item select enable Spanning Tree protocol We are recommended that you enable STP on all switches ensures a single active path on the network 1 You can view spanning tree information about the Root Bridge Such as follow screen 2 You can view spanning tree status about the switch Such as follow ...

Страница 40: ... Tree Protocol configuration messages Enter a number 1 through 10 Forward Delay time You can change forward delay time The number of seconds a port waits before changing from its Spanning Tree Protocol learning and listening states to the forwarding state Enter a number 4 through 30 4 The following parameter can be configured on each port click set Apply button to modify Parameter Description Port...

Страница 41: ... mirror mode Disable Rx Tx Both 2 Monitoring Port It means mirror port can be used to see all monitors port traffic You can connect mirror port to LAN analyzer or netxray 3 Monitored Port The ports you want to monitor All monitor port traffic will be copied to mirror port You can select max 25 monitor ports in the switch User can choose which port that they want to monitor in only one mirror mode ...

Страница 42: ...ns data and then click Apply to update the changes on this page Name Enter a name to be used for the switch Location Enter the location of the switch Contact Enter the name of a person or organization 2 Community strings serve as passwords and can be entered as one of the following RO Read only Enables requests accompanied by this string to display MIB object information RW Read write Enables requ...

Страница 43: ... 43 ...

Страница 44: ...curity Manager On this page user can change user name and password with following steps 1 User name Type the new user name 2 Password Type the new password 3 Reconfirm password Retype the new password 4 Click Apply ...

Страница 45: ... Switch setting Advanced then you still to fill in the authentication server information Radius Server IP Address the IP address of the authentication server Server Port The UDP port number used by the authentication server to authenticate Accounting Port The UDP port number used by the authentication server to retrieve accounting information Shared Key A key shared between this switch and authent...

Страница 46: ...rmine when an EAPOL PDU is to be transmitted Default value is 30 seconds Supplicant Timeout Used to determine timeout conditions in the exchanges between the supplicant and authentication server Default value is 30 seconds Server Timeout Used to determine timeout conditions in the exchanges between the authenticator and authentication server Default value is 30 seconds Max requests Used to determi...

Страница 47: ...ing function for user to check the access of specific host Input the host IP and the counts of ping then press Apply and the result comes as following User can stop pinging anytime by just press Stop button and it will return to Ping IP Address page ...

Страница 48: ...re and remote boot switch system Install TFTP program such as Turbo98 or Cisco TFTP and then execute Copy updated firmware image bin into TFTP server s directory In web management select administrator TFTP update firmware Download new image bin file by pressing update firmware After update finished press reboot to restart switch ...

Страница 49: ...an restore EEPROM value from here but you must put back image in ftp server switch will download back flash image 2 7 2 TFTP Backup Configuration Use this page to set tftp server ip address You can save current EEPROM value from here then go to the TFTP restore configuration page to restore the EEPROM value ...

Страница 50: ... 50 2 8 Reset System Reset Switch to default configuration default value as below 2 9 Reboot Reboot the Switch in software reset ...

Страница 51: ...are There are 2 cases to use 1k X modem to update firmware a User enters 1K X modem receiver mode through pressing any key within 5 seconds after system power on b System automatically enters 1K X modem receiver mode if it detects the firmware checksum fail while booting 1 Press disconnect button when you start 1K X modem modes Press File Properties change boudrate to 57600bps then press OK ...

Страница 52: ... 52 2 Press connected you will see CCCC displayed on console Then select Transfer Send File 3 Select 1K Xmodem in the Protocol item and give the place that image file folder Press Send button ...

Страница 53: ... 53 4 Start download image file 5 Finish download image the switch system will update firmware automatic Update firmware ok the switch will reboot Please change the boudrate to 9600bps ...

Страница 54: ... a serial interface to manage and monitor the switch user can follow the Console Port Information provide by web to use windows HyperTerminal program to link the switch 2 You can type user name and password to login The default user name is admin the default password is 0000 ...

Страница 55: ... the switch Reboot Switch Restart the system or reset switch to default configuration TFTP Update Firmware Use TFTP to download image Logout Exit the menu line program Control Key The control key as follow is provided for this mode operation Tab Move the vernier to next item Backspace Move the vernier to previous item Enter Select item Space Toggle selected item to next configure 4 2 Switch Static...

Страница 56: ... as follow provided in later configure page Actions Quit Exit the page of port configuration and return to previous menu Edit Configure all items Finished configure press Ctrl A Back to action menu line Save Save all configure value Previous Page Return to previous page to configure Next page Go to the next page to configure it ...

Страница 57: ...utput rate control per unit is 100K The valid range is 0 1000 0 disable rate control 1 1000 valid rate value 3 Enabled User can disable or enable this port control Yes that mean the port is enable No that mean the port is disable 4 Auto User can set auto negotiation mode is Auto Nway_Force Force of per port 5 Spd Dpx User can set 100Mbps or 10Mbps speed on port 1 port 24 Set 1000Mbps 100Mbps or 10...

Страница 58: ...able or disable Half User can set half flow control function backpressure as enable or disable NOTE 1 Pressing Save only can save one page configuration 2 If the static trunk groups exist you can see it ex TRK1 TRK2 after port 26 and you can configure all of the items as above ...

Страница 59: ... of TRK1 TRK7 item Static the normal trunk LACP this trunk group have link aggregation control protocol 3 Press Ctrl A to go back action menu line 4 Select Save to save all configure value 5 If the item of TRK1 TRK7 is set Disable it s mean the trunk group is deleted 6 All ports in the same static trunk group will be treated as single port So when you setting VLAN members and Port configuration th...

Страница 60: ... 60 4 2 3 VLAN Configuration 4 2 3 1 VLAN Configure This page can set VLAN mode to port based VLAN or 802 1Q VLAN or disable VLAN function ...

Страница 61: ...ort VID 1 255 Type the PVID 2 NonMember Drop It matches that Ingress Filtering Rule 1 on web Forwarding only packets with VID matching this port s configured VID Press Space key to choose forward or drop the frame that VID not matching this port s configured VID 3 UnTagged Drop It matches that Ingress Filtering Rule 2 on web Drop untagged frame Press Space key to choose drop or forward the untagge...

Страница 62: ...N group ID The group ID rang is 1 4094 4 Member Press Space key to choose VLAN member There are two types to selected a Member the port is member port b No the port is NOT member port 5 Press Ctrl A go back action menu line 6 Select Save to save all configure value NOTE If the trunk groups exist you can see it ex TRK1 TRK2 after port26 and you can configure it is the member of the VLAN or not ...

Страница 63: ...key to choose VLAN member There are three types to selected a UnTagged This port is the member port of this VLAN group and outgoing frames are NO VLAN Tagged frames b Tagged This port is the member port of this VLAN group and outgoing frames are VLAN Tagged frames c NO The port is NOT member of this VLAN group 6 Press Ctrl A go back action menu line 7 Select Save to save all configure value NOTE I...

Страница 64: ...te and then press enter 3 User can modify the protocol VLAN item and the member ports are tagged or un tagged and remove some member ports from this VLAN group 4 After edit VLAN press Save key to save all configures value NOTE 1 When pressing Enter once will complete deletion on delete mode 2 The VLAN Name and VLAN ID cannot modify 3 The default VLAN can t be deleting ...

Страница 65: ... select VLAN groups sorted mode 1 sorted by name 2 Sorted by VID The Edit Delete a VLAN group page will display the result In the Edit Delete a VLAN Group page the result of sorted by name In the Edit Delete a VLAN Group page the result of sorted by VID ...

Страница 66: ... 66 4 2 4 Misc Configuration ...

Страница 67: ...hen back to action menu and press Save Reply Counts will display the result of pinging 4 2 4 2 MAC Age Interval Type the number of seconds that an inactive MAC address remains in the switch s address table The valid range is 300 765 seconds Default is 300 seconds ...

Страница 68: ... Filtering This page is configuring broadcast storm control 1 Press Edit to configure the broadcast storm filter mode 2 Press Space key to choose the threshold value The valid threshold value is 5 10 15 20 25 and NO Default is 5 ...

Страница 69: ...w Queue Max Delay Time To set the time that low priority packets queuing in switch The valid range is 1 255ms Default Max Delay Time is 255ms NOTE Make sure Max bridge transit delay bound control is enabled before enabling Low Queue Delay Bound because Low Queue Delay Bound must be work under Max bridge transit delay bound control is enabled situation 4 2 4 5 Port Security A port in security mode ...

Страница 70: ...e to save all configure value 5 You can press Next Page to configure port9 port26 press Previous Page return to last page 4 2 4 5 Collisions Retry Forever Collisions Retry Forever Disable In half duplex if happen collision will retry 48 times and then drop frame Enable In half duplex if happen collision will retry forever Default ...

Страница 71: ... 71 4 2 4 6 Hash Algorithm Select CRC Hash default or DirectMap for Hash algorithm 4 2 4 7 IFG Compensation Enable or disable the inter frame gap IFG compensation function ...

Страница 72: ... 72 ...

Страница 73: ... 73 4 2 5 Administration Configuration 4 2 5 1 Change Username Use this page user can change web management user name Type the new user name and then press Save item ...

Страница 74: ... 74 4 2 5 2 Change Password Use this page user can change web management login password 4 2 5 3 Device Information This page is provided to the user to configure the device information ...

Страница 75: ... 75 4 2 5 4 IP Configuration User can configure the IP setting and fill in the new value ...

Страница 76: ...sniffer port can be used to see all monitors port traffic Press Space key to choose it 4 Monitored Port The ports you want to monitor All monitor port traffic will be copied to sniffer port You can select max 25 monitor ports in the switch User can choose which port to monitor in only one sniffer mode Press Space key to choose member port V is the member not the member 5 Press Ctrl A go back actio...

Страница 77: ... 77 4 2 7 Priority Configuration 4 2 7 1 Port Static Priority This static priority based on port if you set the port is high priority income frame from this port always high priority frame ...

Страница 78: ...ueue Actions 1 Select Edit 2 Press Space key to select the priority level mapping to high or low queue 3 High Low Queue Service Ration H L User can select the ratio of high priority packets and low priority packets 4 Press Ctrl A go back action menu line 5 Select Save to save all configure value ...

Страница 79: ...s in the switch s address table regardless of whether the device is physically connected to the switch This saves the switch from having to re learn a device s MAC address when the disconnected or powered off device is active on the network again In this page user can add modify delete a static MAC address ...

Страница 80: ...y 3 Port num press Space key to select the port number 4 Vlan ID If tag based 802 1Q VLAN are set up on the switch static addresses are associated with individual VLANs Type the VID to associate with the MAC address 5 Press Ctrl A to go back action menu line 6 Then select Save to save all configure value Edit static MAC address Actions 1 Press Edit key 2 Choose the MAC address that you want to mod...

Страница 81: ... to go back action menu line and then select Save to save all configure value Delete static MAC address Actions 1 Press Delete key 2 Choose the MAC address that you want to delete and then press enter 3 Pressing Enter once will complete deletion on delete mode ...

Страница 82: ... 82 ...

Страница 83: ...user can add modify delete filter MAC address Add filter MAC address Actions 1 Press Add Edit key to add a filter MAC address 2 MAC Address Type the MAC address to filter 3 Vlan ID If tag based 802 1Q VLAN are set up on the switch type the VID to associate with the MAC address 4 Press Ctrl A to go back action menu line and then select Save to save all configure value ...

Страница 84: ... Actions 1 Press Edit key 2 Choose the MAC address that you want to modify and then press enter 3 Press Edit key to modify all the items 4 Press Ctrl A to go back action menu line and then select Save to save all configure value ...

Страница 85: ... 85 ...

Страница 86: ... filter MAC address Actions 1 Press Delete key to delete a filter MAC address 2 Choose the MAC address that you want to delete and then press enter 3 When pressing Enter once will complete deletion on delete mode ...

Страница 87: ...iguration 4 3 1 STP The Spanning Tree Protocol STP is a standardized method IEEE 802 1D for avoiding loops in switched networks When STP enabled to ensure that only one path at a time is active between any two nodes on the network ...

Страница 88: ... 88 4 3 1 1 STP Enable This page is showing the users how to enable or disable Spanning Tree function Press Space key to select enable or disable 4 3 1 2 STP System Configuration ...

Страница 89: ...tions 1 You can view spanning tree information about the Root Bridge on the left 2 On the right user can set new value for STP parameter NOTE All about the parameter description please see the sections 2 4 8 ...

Страница 90: ...es to determine which port are the forwarding ports 4 Priority This means priority port you can make it more or less likely to become the root port 5 Press Ctrl A back to action menu line 6 Select Save to save all configure value 7 On the action menu line you can press Next Page to configure port9 port26 press Previous Page return to last page NOTE All about the parameter description please see th...

Страница 91: ...etwork Management Protocol SNMP can be management the switch Use this page to define management stations as trap managers and to enter SNMP community strings User can also define a name location and contact person for the switch 4 3 2 1 System Options Actions ...

Страница 92: ...Type a name to be used for the switch 3 System Contact Type the name of contact person or organization 4 System Location Type the location of the switch 5 Press Ctrl A go back action menu line 6 Press Save to save the configure value ...

Страница 93: ... name of current strings 2 Write Access Enable the rights is read only or read write Restricted Read only enables requests accompanied by this string to display MIB object information Unrestricted Read write enables requests accompanied by this string to display MIB object information and to set MIB objects ...

Страница 94: ...ite Access Press Space key to select the right is restricted or unrestricted z Edit Community Name 1 Press Edit key choose the item that you want to modify and then press Enter 2 Community Name Type the new name 3 Write Access Press Space key to change the right is restricted or unrestricted ...

Страница 95: ... 95 z Delete Community Name 1 Press Delete key 2 Choose the community name that you want to delete and then press enter 3 When pressing Enter once will complete deletion on delete mode ...

Страница 96: ... trap manager is defined no traps are issued Create a trap manager by entering the IP address of the station and a community string z Add SNMP trap manager 1 Press Add Edit to add the trap manager 2 IP Type the IP address 3 Community Name Type the community name 4 Press Ctrl A go to actions line press Save key to save all configure ...

Страница 97: ...e new IP address 3 Community Name Type the community name 4 Press Ctrl A go to actions line press Save key to save all configure z Delete trap manager 1 Press Delete key 2 Choose the trap manager that you want to delete and then press enter 3 When pressing Enter once will complete deletion on delete mode ...

Страница 98: ...iguration information to be processed by the switch If a device sends a GVRP request using the VID of a VLAN defined on the switch the switch will automatically add that device to the existing VLAN This page you can enable disable the GVRP GARP VLAN Registration Protocol support Actions 1 Select Edit 2 Press Space key to choose Enabled Disabled 3 Press Ctrl A back to action menu line 4 Select Save...

Страница 99: ...ernet Protocol IP suite This page you can enable disable the IGMP support Actions 1 Select Edit 2 IGMP Protocol Press Space key to choose Enable Disable 3 IGMP Query Mode Press Space key to choose Auto Enable Disable 4 Press Ctrl A go back action menu line 5 Select Save to save configure value ...

Страница 100: ... and view all the LACP status Note All ports support LACP dynamic trunk group If connecting to the device that also supports LACP the LACP dynamic trunk group will be created automatically 4 3 5 1 Working Port Setting This page can set the actually work ports in trunk group ...

Страница 101: ...e set this page you have to set trunk group on the page of Trunk Configuration first 4 3 5 2 State Activity Actions 1 Select Edit 2 Press Space key to choose the item Active The port automatically sends LACP protocol packets Passive The port does not automatically send LACP protocol packets and responds only if it receives LACP protocol packets from the opposite device 3 Press Ctrl A go back actio...

Страница 102: ... 102 4 3 5 3 LACP Status When you re setting trunk group you can see the relational information here Static trunk group LACP trunk group ...

Страница 103: ... 103 Actions Quit Exit this page and return to previous menu Previous Page Return to previous page to view Next page Go to the next page to view ...

Страница 104: ... 104 4 3 6 802 1x Protocol This page can configure and view all the 802 1x status 4 3 6 1 802 1x Enable 1 Select Edit 2 Press Space key to choose Enabled Disabled ...

Страница 105: ... 105 3 Press Ctrl A go back action menu line 4 Select Save to save configure value ...

Страница 106: ...this switch and authentication server 4 NAS Identifier A string used to identify this switch 5 Server Port The UDP port number used by the authentication server to authenticate 6 Accounting Port The UDP port number used by the authentication server to retrieve accounting information 7 Press Ctrl A go back action menu line 8 Press Save to save configure value ...

Страница 107: ...y to choose Fu Fa Au No authorization status 3 Press Ctrl A go back action menu line 4 Select Save to save all configure value Note Fu Force the specific port to be unauthorized Fa Force the specific port to be authorized Au The state of the specific port was determined by the outcome of the authentication No The specific port didn t support 802 1x function ...

Страница 108: ...thentication server Default value is 30 seconds 5 Server Timeout Used to determine timeout conditions in the exchanges between the authenticator and authentication server Default value is 30 seconds 6 ReAuthMax Used to determine the number of re authentication attempts that are permitted before the specific port becomes unauthorized Default value is 2 times 7 Reauth Period Used to determine a nonz...

Страница 109: ...tatus and Counters You can press the key of Tab or Backspace to choose item and press Enter key to select item 4 4 1 Port Status This page display every port status Link Status Display the port is link or no link ...

Страница 110: ...peed and duplex FlowCtrl In auto Nway force mode display the flow control status is enable or not after negotiation In force mode display the flow control status is enabling or disable depending on user setting Actions Quit Exit the page of port status and return to previous menu Previous Page Display previous page Next page Display next page 4 4 2 Port Counters The following information provides ...

Страница 111: ...ion Display the board number Serial number Display the serial number assigned by manufacturer Module 1 Type Display the module 1 Type 1000Tx or 100Fx ext Depend on module card mode Module 1 information Display the information saved in EEPROM of module1 Module 2 Type Display the module 2 Type 1000Tx or 100Fx ext Depend on module card mode Module 2 information Display the information saved in EEPROM...

Страница 112: ... 112 4 5 Reboot Switch 4 5 1 Default Reset switch to default configuration default value please section 2 4 14 4 5 2 Restart Reboot the switch in software reset ...

Страница 113: ...13 4 6 TFTP Update Firmware This page provide user to update firmware or restore EEPROM value or upload current EEPROM value 4 6 1 TFTP Update Firmware This page provides user use TFTP to update firmware ...

Страница 114: ...7 When save successfully the image file download finished too 8 Restart switch 4 6 2 Restore Configure File This page user can restore EEPROM value save image file before form TFTP server Actions 1 Start the TFTP server 2 Press Edit on this page 3 TFTP Server Type the IP of TFTP server 4 Remote File Name Type the image file name 5 Press Ctrl A go to action line 6 Press Save key it will start to do...

Страница 115: ...restore the EEPROM value Actions 1 Start the TFTP server 2 Press Edit on this page 3 TFTP Server Type the IP of TFTP server 4 Remote File Name Type the image file name 5 Press Ctrl A go to action line 6 Press Save key it will start to upload the image file 7 When save successfully the image file upload finished too 8 Restart switch ...

Страница 116: ...s As a result each group of stations connected to separate Segmented Ports forms different isolated Broadcast Domain The Broadcast Sharing Ports should be used to connect servers and other common services such as Internet access that are used by all the stations connected to the different Segmented Ports Virtual LAN or VLAN is generally defined as broadcast domain It can be viewed as a group of en...

Страница 117: ...gical groups when needed z Network administrators can easily fine tune the network z Keeping network structure from the physical topology of the cabling z Making large networks more manageable You can group users according to some shared characteristic such as a common business function or a common protocol A single switch may have several independent VLANs within it Below is a example that R D Ma...

Страница 118: ...or higher bandwidth service required You can use trunking to improve the throughput between segments Moreover this switch furtherly provides trunk with fail over function that is when one of the links of trunk is fail or broken the traffic originally go through that link will be automatically re direct to other links of trunk this give the trunk with redundancy and greatly increase the value of tr...