10
Measurement must be carried out as follows:
– Measure from metal to metal in the hook opening, not including
the hook safety catch.
– The abrasion of the hook surface must not exceed 10 %
of the actual value.
– Determine the lateral torsion of the hook!
In the event of twisting that exceeds 10 degrees beyond flatness,
the hook must be replaced.
– Check the hook safety catch for tight closure and smooth
operation! Replace if damaged!
– Excessive damage due to chemical or corrosive influences
require replacement of the hooks.
– Do not repair a hook by welding or grinding!
These tests are to be carried out
qualified
specialists for hoisting equipment only. If you
do not have this knowledge, please contact your supplier or us. We perform regular
testing, also within the framework of the
Maintenance Agreement.
Maintenance
When you stop using the equipment, pay attention to the following:
– Wipe off dirt and water, lightly oil the chain and the rotating parts of the hooks.
– From time to time - depending on the frequency of use - check whether there is still
a sufficient amount of grease the gear wheels.
Lubrication specification
Put a thin coat of Molykote grease on all mechanically moving parts (gear wheels, etc.).
Exception:
Brake components must not be lubricated!
When not in use, hang the chain hoist up in a dry place.
Please note that safe and problem-free operation is only guaranteed if original spare
parts are used.
If you would like to have the device checked or repaired within the scope of the
guarantee, please send in the device in the assembled condition.
If you are sending in dismantled devices, we are unfortunately no longer able to accept
warranty claims.