1. Introduction

1.1 Checklist

Check the contents of your package for following parts:

VC-201A / VC-202A / VC-204 x 1

5V DC / 2A AC-to-DC Power Adapter x 1

RJ-11 Telephone Line x 1 (VC-201A / VC-204 only)

User’s Manual x 1

If  any  of  these  items  are  missing  or  damaged,  please  contact 
your  dealer  immediately,  if  possible,  retain  the  carton  including 
the  original  packing  material,  and  use  them  against  to  repack 
the product in case there is a need to return it to us for repair.

1.2 Ethernet over VDSL2 Bridge Description

PLANET’s  state-of-the-art  Ethernet-over-VDSL2  products  are 
based  on  two  core  networking  technologies: 

Ethernet  and 

VDSL2  (Very-high-data-rate  Digital  Subscriber  Line 
2).

  This  technology  offers  the  absolute  fastest  possible  data 

transmission  speeds  over  existing  copper  telephone  lines  or 
coaxial cables without the need for rewiring.

The  VC-201A  /  VC-202A  /  VC-204  Ethernet  Over  VDSL2 
Converter  has  a  switching  architecture  with  RJ-45  10/100Mbps 
Ethernet  port  and  one  asymmetric  or  symmetric  Ethernet  over 
VDSL  port  (Asymmetric  means  upstream  and  downstream 
rate  are  not  the  same  and  Symmetric  means  upstream  and 
downstream  rate  are  similar)    –  the  VDSL  port  can  be  RJ-11 
connector  (VC-201A  /  VC-204)  or  BNC  Connector  (VC-202A). 

The  VC-201A  /  VC-202A  /  VC-204  can  be  set  to  Central  Office 

(CO)  or  Customer  Premises  Equipment  (CPE)  mode  via  a  DIP 
switch. When VC-20X-CO (VC-201A / VC-204) is connected with 
other  VC-20X-CPE  (VC-201A  /  VC-204)  device,  the  performance 

l

l

l

l

Содержание VC-201A

Страница 1: ...Ethernet over VDSL2 Converter VC 201A VC 202A VC 204 User s Manual...

Страница 2: ...se PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is s...

Страница 3: ...user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the use...

Страница 4: ...tronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to col...

Страница 5: ...cations 11 2 Hardware Description 14 2 1 Front Panel 15 2 2 The Rear Panel 19 3 Installation 22 3 1 Install Ethernet over VDSL2 Converter 22 3 2 Connecting VC 201A VC 202A VC 204 25 3 3 Connecting VC...

Страница 6: ...DSL2 Very high data rate Digital Subscriber Line 2 This technology offers the absolute fastest possible data transmission speeds over existing copper telephone lines or coaxial cables without the need...

Страница 7: ...tion for existing Long Reach Ethernet LRE networks The cable specifications of the connection are listed as following 10Base T Category 3 4 or 5 UTP 100Base TX Category 5 5e or 6 UTP Ethernet over VDS...

Страница 8: ...ver VDSL and Telephone Network LAN2 LAN1 Up to 1 6km Up to 3 0km Coaxial Cable VC 201A CPE VC 201A CO Main office PBX Telco CO wire closet VC 204 CPE VC 204 CO Ethernet over VDSL and Telephone Network...

Страница 9: ...hone Network IP Camera IP Camera Ethernet Switch CAM Viewer Coaxial Coaxial VC 202A CPE MC 700 Chassis VC 202A CO VDSL2 VDSL2 VDSL2 VDSL2 LAN1 VC 201A CPE VC 204 CPE Ethernet over VDSL and Telephone N...

Страница 10: ...rds DMT Discrete Multi Tone line coding Half Duplex Back Pressure and IEEE 802 3x Full Duplex Pause Frame Flow Control Built in POTS splitter to share voice and data VC 201A and VC 204 Voice and data...

Страница 11: ...ctable fast and interleaved mode Selectable target Band Plan Selectable target SNR mode Encoding VDSL DMT ITU T G 993 1 VDSL ITU T G 997 1 ITU T G 993 2 VDSL2 Profile 17a Support LED Indicators One Po...

Страница 12: ...44 15Mbps 2200m 35 12Mbps 2400m 32 10Mbps 2600m 29 8Mbps 2800m 27 6Mbps 3000m 25 5Mbps Symmetric Mode 200m 100 100Mbps 400m 90 95Mbps 600m 70 70Mbps 800m 55 50Mbps 1000m 45 35Mbps 1200m 30 25Mbps 140...

Страница 13: ...non condensing Standard Conformance Regulation Compliance FCC Part 15 Class A CE Standards Compliance IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3x Full Duplex Pause frame Flow Control ITU T...

Страница 14: ...rt and VC 204 provides 4 RJ 45 ports with two different running speed 10Mbps and 100Mbps It will distingish the speed of incoming connection automatically This section describes the hardware features...

Страница 15: ...panel provides a simple interface monitoring the Ethernet over VDSL2 Converter VC 201A Front Panel Figure 2 1 VC 201A front panel VC 202A Front Panel Figure 2 2 VC 202A front panel VC 204 Front Panel...

Страница 16: ...R Green Light Power ON Off Power OFF VDSL LED Color Function LNK ACT Green Light Indicate that the VDSL link is established Fast Blink Indicate that the VDSL link is at training status about 10 second...

Страница 17: ...at port Off Indicate that the port is Link Down 100 Green Light Indicate that the port is operating at 100Mbps Off Indicate that the port is Link Down or 10Mbps 2 1 2 LED indicators for VC 204 The ric...

Страница 18: ...ast Blink Indicate that the VDSL link is at training status about 10 seconds Slow Blink Indicate that the VDSL link is at idle status CO Green Light Indicate the VDSL Bridge is running at CO mode CPE...

Страница 19: ...04 rear panel 2 2 1 MODE DIP Switch The Ethernet over VDSL2 Converter provides 4 selective transmission modes By switching the transmission modes you can obtain a best transmission mode to suit with p...

Страница 20: ...P Camera or Wireless Access Point and etc network devices Note When the Ethernet Over VDSL2 Converter operate at CPE mode the DIP switch 2 3 4 is no function Fast and Interleave mode Fast mode guarant...

Страница 21: ...Jack VC 201A VC 202A VC 204 require 5V DC power input It will conform to the bundled AC adapter If you have the issue to make the power connection please contact your local sales representative Note...

Страница 22: ...o Point connection only Master device to Slave device and has equipped with 2 RJ 11 connectors for VDSL port One for voice device connection like telephone and the other one for network link connectio...

Страница 23: ...55Mbps asymmetric backbone but one Ethernet over VDSL2 Converter must be Master CO mode and the other one is Slave CPE mode VDSL2 CPE Converter VDSL2 CO Converter Internet Up to 1 6km Router Switch P...

Страница 24: ...tall a Slave VC 201A VC 204 CPE converter on the individual client side and connect to the Multi port Master through the telephone lines When deciding where to put the converter then you must ensure I...

Страница 25: ...01A by connecting its power source 3 Power LED will illuminate 4 Connect VDSL line from another VDSL device to VDSL port of the VC 201A 5 LNK LED will blink to illuminate 6 Connect telephone to the PH...

Страница 26: ...NK LED will illuminate 6 Connect telephone to the PHONE port 7 VC 201A Connect Ethernet port to Ethernet Switch or Broad band Router via regular Cat 5 5e or 6 cables VC 204 Connect per Ethernet port t...

Страница 27: ...C 202A by connecting its power source 3 Power LED will illuminate 4 Connect coaxial cable from another VDSL device to VDSL BNC port of the VC 202A 5 LNK LED will blink for illuminating 6 Connect Ether...

Страница 28: ...nect coaxial cable from another VDSL device to VDSL BNC port of the VC 202A 5 LNK LED will illuminate 6 Connect Ethernet port to Ethernet Switch or Broadband Router via regular Cat 5 5e or 6 cables VC...

Страница 29: ...er chassis Figure 3 8 Insert a VDSL2 converter into an available slot Step 3 Attach a rack mount bracket to each side of the Converter Chassis with supplied screws attached to the package Step 4 After...

Страница 30: ...ntered the issue to make the power connection please contact your local sales representative Please keep the AC DC adapter as spare parts when your VC 201A VC 202A are installed to a Media Chassis 2 5...

Страница 31: ...h CPE mode connect to each other to make it work SYMPTOM TP LED does not light after cable is connected to the port CHECKPOINT 1 Verify you are using the Cat 5 5e or 6 cables with RJ 45 connector to c...

Страница 32: ...ucture Q3 What is the best distance for VC 201A VC 202A VC 204 A3 In order to guarantee the stability and better quality of network so we would suggest the distance within 1 6 kilo meter is the best f...

Страница 33: ...tting computer or terminal to resend some packets of data SNR measures the quality of a transmission channel over a network channel The greater the ratio the easier it is to identify and subsequently...

Страница 34: ...This page is intentionally left blank...

Страница 35: ...This page is intentionally left blank...

Страница 36: ...This page is intentionally left blank...

Отзывы: