Coaxial Cable

Up to 3.0km

Router

Switch

VDSL2 CPE Converter

VDSL2 CO Converter

Internet

VDSL2

100Base-TX UTP

VDSL2 Coaxial Cable

VDSL2

Figure 3-3:

  VC-202A LAN to LAN connection

3.1.2 VC-201A / VC-204 Connect to Multi-Port Master

To  built  up  a  local  Internet  in  apartment,  hotel,  campus  and 
hospitality environment.

The  Multi-port  Master  (for  example,  VC-820M  VDSL2  Switch) 

need to be placed in the wiring center (MDF room) and connect 
to  the  telephone  line  system,  on  the  other  hand,  need  to  install 
a  Slave  (VC-201A  /  VC-204  CPE)  converter  on  the  individual 
client  side  and  connect  to  the  Multi-port  Master  through  the 
telephone lines.

When  deciding  where  to  put  the  converter  then  you  must 
ensure:

It is accessible and cables can be connected easily.

Cabling  is  away  from  sources  of  electrical  noise  such  as 

radios,  transmitters  and  power  lines  and  fluorescent  lighting 
fixtures.

Water or moisture can not enter the Converter.

Air  flow  around  the  unit  and  through  the  vents  in  the  side 

of  the  case  is  not  restricted  (company  recommend  that  you 
provide a minimum of 25mm inch clearance)

To prolong the operational life of your units:

Do not place objects on top of any unit or stack

l

l

l

l

l

Содержание VC-201A

Страница 1: ...Ethernet over VDSL2 Converter VC 201A VC 202A VC 204 User s Manual...

Страница 2: ...se PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is s...

Страница 3: ...user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the use...

Страница 4: ...tronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to col...

Страница 5: ...cations 11 2 Hardware Description 14 2 1 Front Panel 15 2 2 The Rear Panel 19 3 Installation 22 3 1 Install Ethernet over VDSL2 Converter 22 3 2 Connecting VC 201A VC 202A VC 204 25 3 3 Connecting VC...

Страница 6: ...DSL2 Very high data rate Digital Subscriber Line 2 This technology offers the absolute fastest possible data transmission speeds over existing copper telephone lines or coaxial cables without the need...

Страница 7: ...tion for existing Long Reach Ethernet LRE networks The cable specifications of the connection are listed as following 10Base T Category 3 4 or 5 UTP 100Base TX Category 5 5e or 6 UTP Ethernet over VDS...

Страница 8: ...ver VDSL and Telephone Network LAN2 LAN1 Up to 1 6km Up to 3 0km Coaxial Cable VC 201A CPE VC 201A CO Main office PBX Telco CO wire closet VC 204 CPE VC 204 CO Ethernet over VDSL and Telephone Network...

Страница 9: ...hone Network IP Camera IP Camera Ethernet Switch CAM Viewer Coaxial Coaxial VC 202A CPE MC 700 Chassis VC 202A CO VDSL2 VDSL2 VDSL2 VDSL2 LAN1 VC 201A CPE VC 204 CPE Ethernet over VDSL and Telephone N...

Страница 10: ...rds DMT Discrete Multi Tone line coding Half Duplex Back Pressure and IEEE 802 3x Full Duplex Pause Frame Flow Control Built in POTS splitter to share voice and data VC 201A and VC 204 Voice and data...

Страница 11: ...ctable fast and interleaved mode Selectable target Band Plan Selectable target SNR mode Encoding VDSL DMT ITU T G 993 1 VDSL ITU T G 997 1 ITU T G 993 2 VDSL2 Profile 17a Support LED Indicators One Po...

Страница 12: ...44 15Mbps 2200m 35 12Mbps 2400m 32 10Mbps 2600m 29 8Mbps 2800m 27 6Mbps 3000m 25 5Mbps Symmetric Mode 200m 100 100Mbps 400m 90 95Mbps 600m 70 70Mbps 800m 55 50Mbps 1000m 45 35Mbps 1200m 30 25Mbps 140...

Страница 13: ...non condensing Standard Conformance Regulation Compliance FCC Part 15 Class A CE Standards Compliance IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3x Full Duplex Pause frame Flow Control ITU T...

Страница 14: ...rt and VC 204 provides 4 RJ 45 ports with two different running speed 10Mbps and 100Mbps It will distingish the speed of incoming connection automatically This section describes the hardware features...

Страница 15: ...panel provides a simple interface monitoring the Ethernet over VDSL2 Converter VC 201A Front Panel Figure 2 1 VC 201A front panel VC 202A Front Panel Figure 2 2 VC 202A front panel VC 204 Front Panel...

Страница 16: ...R Green Light Power ON Off Power OFF VDSL LED Color Function LNK ACT Green Light Indicate that the VDSL link is established Fast Blink Indicate that the VDSL link is at training status about 10 second...

Страница 17: ...at port Off Indicate that the port is Link Down 100 Green Light Indicate that the port is operating at 100Mbps Off Indicate that the port is Link Down or 10Mbps 2 1 2 LED indicators for VC 204 The ric...

Страница 18: ...ast Blink Indicate that the VDSL link is at training status about 10 seconds Slow Blink Indicate that the VDSL link is at idle status CO Green Light Indicate the VDSL Bridge is running at CO mode CPE...

Страница 19: ...04 rear panel 2 2 1 MODE DIP Switch The Ethernet over VDSL2 Converter provides 4 selective transmission modes By switching the transmission modes you can obtain a best transmission mode to suit with p...

Страница 20: ...P Camera or Wireless Access Point and etc network devices Note When the Ethernet Over VDSL2 Converter operate at CPE mode the DIP switch 2 3 4 is no function Fast and Interleave mode Fast mode guarant...

Страница 21: ...Jack VC 201A VC 202A VC 204 require 5V DC power input It will conform to the bundled AC adapter If you have the issue to make the power connection please contact your local sales representative Note...

Страница 22: ...o Point connection only Master device to Slave device and has equipped with 2 RJ 11 connectors for VDSL port One for voice device connection like telephone and the other one for network link connectio...

Страница 23: ...55Mbps asymmetric backbone but one Ethernet over VDSL2 Converter must be Master CO mode and the other one is Slave CPE mode VDSL2 CPE Converter VDSL2 CO Converter Internet Up to 1 6km Router Switch P...

Страница 24: ...tall a Slave VC 201A VC 204 CPE converter on the individual client side and connect to the Multi port Master through the telephone lines When deciding where to put the converter then you must ensure I...

Страница 25: ...01A by connecting its power source 3 Power LED will illuminate 4 Connect VDSL line from another VDSL device to VDSL port of the VC 201A 5 LNK LED will blink to illuminate 6 Connect telephone to the PH...

Страница 26: ...NK LED will illuminate 6 Connect telephone to the PHONE port 7 VC 201A Connect Ethernet port to Ethernet Switch or Broad band Router via regular Cat 5 5e or 6 cables VC 204 Connect per Ethernet port t...

Страница 27: ...C 202A by connecting its power source 3 Power LED will illuminate 4 Connect coaxial cable from another VDSL device to VDSL BNC port of the VC 202A 5 LNK LED will blink for illuminating 6 Connect Ether...

Страница 28: ...nect coaxial cable from another VDSL device to VDSL BNC port of the VC 202A 5 LNK LED will illuminate 6 Connect Ethernet port to Ethernet Switch or Broadband Router via regular Cat 5 5e or 6 cables VC...

Страница 29: ...er chassis Figure 3 8 Insert a VDSL2 converter into an available slot Step 3 Attach a rack mount bracket to each side of the Converter Chassis with supplied screws attached to the package Step 4 After...

Страница 30: ...ntered the issue to make the power connection please contact your local sales representative Please keep the AC DC adapter as spare parts when your VC 201A VC 202A are installed to a Media Chassis 2 5...

Страница 31: ...h CPE mode connect to each other to make it work SYMPTOM TP LED does not light after cable is connected to the port CHECKPOINT 1 Verify you are using the Cat 5 5e or 6 cables with RJ 45 connector to c...

Страница 32: ...ucture Q3 What is the best distance for VC 201A VC 202A VC 204 A3 In order to guarantee the stability and better quality of network so we would suggest the distance within 1 6 kilo meter is the best f...

Страница 33: ...tting computer or terminal to resend some packets of data SNR measures the quality of a transmission channel over a network channel The greater the ratio the easier it is to identify and subsequently...

Страница 34: ...This page is intentionally left blank...

Страница 35: ...This page is intentionally left blank...

Страница 36: ...This page is intentionally left blank...