Planet IVC-234GT Скачать руководство пользователя страница 3

is likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense.

CE Mark Warning

This is a Class A product. In a domestic environment, this product may 
cause radio interference, in which case the user may be required to 
take adequate measures.

Energy Saving Note of the Device

This power required device does not support Standby mode operation. 
For energy saving, please remove the power cable to disconnect the 
device from the power circuit. Without removing power cable, the 
device will still consume power from the power source. In view of 
Saving the Energy and reducing the unnecessary power consumption, it 
is strongly suggested to remove the power connection for the device if 
this device is not intended to be active.

WEEE Warning

To avoid the potential effects on the environment and human 
health as a result of the presence of hazardous substances 
in electrical and electronic equipment, end users of electrical 
and electronic equipment should understand the meaning of 

the crossed-out wheeled bin symbol. Do not dispose of WEEE as 
unsorted municipal waste and have to collect such WEEE separately.

Revision

PLANET Industrial 1-Port BNC/RJ11 to 4-Port Gigabit Ethernet Extender 
User’s Manual

For Models:

 IVC-234GT

Revision:

 1.0 (May 2018)

Part No.:

 2350-AC0530-000

Содержание IVC-234GT

Страница 1: ...Industrial 1 Port BNC RJ11 to 4 Port Gigabit Ethernet Extender IVC 234GT User s Manual...

Страница 2: ...mes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right...

Страница 3: ...ower from the power source In view of Saving the Energy and reducing the unnecessary power consumption it is strongly suggested to remove the power connection for the device if this device is not inte...

Страница 4: ...oduct Specifications 12 4 Applications 14 4 1 Point to Point Application LAN to LAN Connection 14 4 2 Point to Multi point Application IP surveillance 16 5 Installations 17 5 1 Wiring the Power Inputs...

Страница 5: ...he Industrial Ethernet Extender and carefully unpack it The box should contain the following items Industrial Ethernet Extender x 1 User s Manual x 1 RJ11 RJ45 Dust Caps Wall mount Kit If any of these...

Страница 6: ...CO VDSL FAULT BNC BNC RJ11 RJ11 4 3 2 1 1000 10 100 CO G INP Asymm 12dB CPE Inter Symm 8dB Input DC12 48V AC 24V V1 V1 V2 V2 PWR1 PWR2 Fault 1A 24V Top View Side View Front View Mounting Kit Mounting...

Страница 7: ...12dB CPE Inter Symm 8dB VDSL Port Figure 2 2 IVC 234GT Front Panel The unit s front panel provides the following simple interfaces LEDs for Power 1 Power 2 and VDSL2 4 10 100 1000BASE T RJ45 ports BN...

Страница 8: ...m LED Color Function P1 Green Lights to indicate DC power input 1 has power P2 Green Lights to indicate DC power input 2 has power Fault Red Lights to indicate that DC power has failed VDSL LED Color...

Страница 9: ...a over that port at 100Mbps or 10Mbps Off Indicates that the port is link down or 1000Mbps 2 5 DIP Switch and Link Type Link Type The BNC mode allows Industrial Ethernet Extender to connect and transf...

Страница 10: ...remises Equipment The Slave device mode usually the CPE device is located at branch office home or remote side as the long reach data receiver The CPE can be connected to the PC IP camera or wireless...

Страница 11: ...nd plan supported the symmetric mode can provide almost the same rate of downstream and upstream DIP 4 SNR Signal Noise Ratio Margin When the SNR margin is selected the system provides 12dB 8dB SNR ma...

Страница 12: ...nsmission 3 937ft RJ11 1 VDSL2 RJ11 female phone jack Twisted pair telephone wires AWG 24 or better up to 1 2km 3 937ft Functionality DIP 1 Select CO or CPE mode DIP 2 Select G INP or Interleaved mode...

Страница 13: ...ds Compliance IEEE 802 3 Ethernet IEEE 802 3u Fast Ethernet IEEE 802 3ab Gigabit Ethernet ITU T G 993 1 VDSL ITU T G 997 1 ITU T G 993 2 VDSL2 Profile 17a 30a Support ITU T G 993 5 G Vectoring and G I...

Страница 14: ...of the Industrial Ethernet Extender could be used to link two local area networks that are located in different places Through the coaxial cable it could set up a 200 100Mbps asymmetric backbone but...

Страница 15: ...LAN 1 in the CO mode from the DIP switch 2 LAN2 Set the Industrial Ethernet Extender at LAN 2 in the CPE mode from the DIP switch 3 Power on the Industrial Ethernet Extender CO and CPE at both sides b...

Страница 16: ...llowing procedure to set up many pairs of IVC 234GT to IP surveillance system 1 Set the IVC 234GT to be the CO and CPE mode from the DIP switch on the front panel 2 Power on the IVC 234GT by connectin...

Страница 17: ...ning the wire clamp screws make sure the power is OFF to prevent from getting an electric shock 1 Insert positive and negative DC power wires into Contacts 1 and 2 for Power 1 or 5 and 6 for Power 2 I...

Страница 18: ...en forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts 1 2 3 4 5 6 Fault Alarm Contacts The Fault Alarm Contacts are energized CLOSE for n...

Страница 19: ...s screwed on the Industrial Ethernet Extender when out of factory Please refer to the following steps for DIN rail mounting Step 1 Screw the DIN rail bracket on the Industrial Ethernet Extender Step 2...

Страница 20: ...N rail is tightly secured on the track Step 4 Please refer to the following procedure to remove the Industrial Ethernet Extender from the track 1 2 Step 5 Lightly pull out the bottom of DIN rail for r...

Страница 21: ...thernet Extender with a screwdriver Step 2 Place the wall mount plate on the rear panel of the Industrial Ethernet Extender Step 3 Use the screws to screw the wall mount plate on the Industrial Ethern...

Страница 22: ...148 132 136 400 67 164 59 146 118 119 103 104 600 38 116 28 94 71 75 59 60 800 24 59 22 49 49 36 38 27 1000 9 45 7 40 21 25 15 24 1200 6 30 3 28 16 24 6 20 CO DIP Switch Distance meter G INP Upstream...

Страница 23: ...2 5 29 20 25 19 28 1200 5 27 3 28 13 27 15 20 CO DIP Switch Distance meter G INP Upstream Downstream Asymmetric Symmetric 8dB 12dB 8dB 12dB 200 89 185 79 166 140 144 117 123 400 57 155 47 137 104 113...

Страница 24: ...h other work SYMPTOM TP LED does not light up after cable is connected to the port CHECKPOINT 1 Verify you are using the Cat 5e or better cable with RJ45 connector to connect to the port 2 If your dev...

Страница 25: ...a measure of signal strength relative to background noise The ratio is usually measured in decibels dB In digital communications the SNR will probably cause a reduction in data speed because of freque...

Страница 26: ...need more support information please contact PLANET switch support team PLANET online FAQs http www planet com tw en support faq Switch support team mail address support planet com tw Copyright PLANET...

Страница 27: ...the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on 2014 30 EU For the evaluation regarding...

Страница 28: ......

Отзывы: