
17
5. Installations
5.1 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial
Ethernet Extender is used for two DC redundant power inputs. Please
follow the steps below to insert the power wire.
Caution
When performing any of the procedures like inserting
the wires or tightening the wire-clamp screws, make
sure the power is OFF to prevent from getting an electric
shock.
1. Insert positive and negative DC power wires into Contacts 1 and 2
for Power 1, or 5 and 6 for Power 2.
Input
DC12~48V, AC 24V
V1+ V1-
V2+ V2-
PWR1
PWR2
Fault
1A@24V
1 2 3 4 5 6
2. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
1
2
3
4
5
6
Power 1
Fault
Power 2
+
-
+
-
Note
1. The wire gauge for the terminal block should be in the
range between 12 and 24 AWG.
2. The DC power input range is 12V ~ 48V DC, 24V AC.
Содержание IVC-234GT
Страница 1: ...Industrial 1 Port BNC RJ11 to 4 Port Gigabit Ethernet Extender IVC 234GT User s Manual...
Страница 28: ......