10
7. Starting Web Management
The following shows how to start up the
Web Management
of the Industrial
Managed Switch. Note the Industrial Managed Switch is configured through an
Ethernet connection. Please make sure the manager PC must be set on the same
IP subnet address
.
For example, the default IP address of the Industrial Managed Switch is
192.168.0.100
, then the manager PC should be set at
192.168.0.x
(where x
is a number between 1 and 254, except 100), and the default subnet mask is
255.255.255.0.
PC / Workstation
with Web Browser
192.168.0.x
Managed Switch
RJ45/UTP Cable
IP Address:
192.168.0.100
Figure 7-1:
IP Management Diagram
Logging in the Industrial Managed Switch
1. Use Internet Explorer 8.0 or above Web browser and enter IP address
http://192.168.0.100
(the factory default IP address or the one that you have
just changed in console) to access the Web interface.