User’s Manual of ICS-10x
-47-
4.4.6 Pair Connection– Local Mode
The parameter defines the maintenance status for listen for the pair connection
.
To make a long distance communication
between two serial equipment, configure two ICS-10x with Pair Connection mode and setup one as a Master (Local side)
and the other as a Slave (Remote side).
Pair Connection – Local (Master)
– the ICS-10x is locate close to the Host Computer or control device and
connect to it via serial interface.
Pair Connection – Remote (Slave)
– the ICS-10x is locate close to the remote serial equipment and connect to
it via serial interface.
Figure 4-46
Pair Connection mode
In effect, this converter will be acting as a TCP server. The screen in Figure 4-47 appears. When the changed operation
mode, the user should be changed the Serial Port Configuration.
Figure 4-47
Pair Connection – Local (Master) Configuration screen
TCP Port Number
The TCP port that ICS-10x uses to listen to connections and that other device
must use to contact ICS-10x. To avoid conflicts with well known TCP ports, the
default is set to
“23”
.
Inactive Timeout
Use the parameter to set an inactive timeout. The unit drops the connection if
there is no activity on the serial line before the set time expires. To disable the
inactive timeout enter
“0”.