2.3.6 Alive Check
The GSD/GSW 802.3at PoE+ Switch series can be configured to monitor connected
PD’s status in real time via traffic detection. Once there is no traffic at interval
time, the GSD/GSW 802.3at PoE+ Switch series is going to restart PoE port power,
and bring the PD back to work. It will greatly enhance the reliability and reduce
administrator management burden.
Object
Description
Port
Select the port number to enable Alive Check.
Status
Allows user to enable or disable per port PD Alive Check
function. All ports are
disabled
as default value.
Startup Time
(60~300s)
PD startup time.
This startup time is based on determining when to start to
measure the traffic. The default startup time is 180 seconds.
Interval Time
(60~300s)
Traffic detection counter.
The switch detects no traffic during this time and countdown
for interval time begins and port begins to reboot. The default
interval time is 180 seconds.
Power Off
(5~60s)
PoE Port Disable Timer
This column allows user to set the PoE device rebooting time.
The default power off time is 5 seconds.