EL640.200-SK Operations Manual (020-0348-00B)
14
Environmental
Table 9. Environmental Characteristics.
Temperature
Operating
-40°C to +85°C
Non-operating
-50°C to +105°C*
Operating Survival
-45°C to +105°C**
Humidity
Non-condensing, operating
93% RH @ 40ºC, per IEC 68-2-3
Condensing, non-operating
95% RH @ 25-55°C, per IEC 68-2-30
Altitude
Operating/non-operating
0 to 18 km (58k ft) per IEC 68-2-13
Vibration
operating/ non-operating
Random, 0.02 g
2
/Hz, 5-500 Hz, 30 minutes
each axis per IEC 68-2-34
operating/ non-operating
Sinusoidal, 1.50 mm amplitude, 10 g max.,
10-55-10 Hz, 1 min./cycle, 60 minutes each axis
Shock
operating/ non-operating
100 g, 6 ms, half sine wave, per IEC 68-2-27
* After 12 hours at -50°C, acclimatize the display at -40°C min. before power on.
** Operating survival: at extremes for 1 hour maximum.