Chimney
Existing flue
-
The chimney must comply with the Current Building Regulations. If in doubt, consult your
Dealer or local Building Inspector.
-
The flue must be in good condition and must provide sufficient draught (refer to technical
details p.
30
).
-
The flue must be suitable for the installation of solid fuel
burning appliances and comply with the Current Building
Regulations.
-
The flue must be clean. It should be swept to remove soot and
dislodge tar deposits.
-
The flue must be well insulated. If the flue inner wall surfaces
are cold, a good thermal draw is impossible causing
condensation problems (tar formation etc) to occur.
-
The flue must not be shared with other appliances.
-
The chimney must be at least 4.5 m (15 ft high).
-
In case of a flat roof or when the roof gradient is lower than 15°, the stack must be 1,2 m (4
feet) high at least.
-
If the chimney has any down draught tendency, due to its position in relation to nearby
obstacles, then an anti-down draught cowl must be installed on the chimney or the chimney
height must be increased.
-
If the decompression in the chimney is excessive, a draught stabiliser must
be installed.
Chimney to be built – New flue
-
The chimney must comply with the Current Building Regulations. If in doubt, consult your
Dealer or local Building Inspector.
-
The appliance must not support the weight of the flue.
-
Consult a chimney specialist for advice on suitable flue systems for solid fuel appliances.
-
It must be distant from any combustible material (walls, cross members)
-
It must permit an easy sweeping
.
Page 34/72
Authentic 35
Содержание Authentic 35
Страница 2: ...Authentic 35 2 72...
Страница 14: ...Authentic 35 Page 14 72...
Страница 16: ...Page 16 72 Authentic 35...
Страница 29: ...Page 29 72 Authentic 35...
Страница 42: ...Page 42 72 Authentic 35...
Страница 55: ...Page 55 72 Authentic 35...
Страница 68: ...Zajedni ki dio Partie Commune Common Part Gemeinsamer Teil Parte Comune Page 68 72 Authentic 35...
Страница 69: ...Sklop gornje plo e Dessus Top Oberseite Parte Superiore Page 69 72 Authentic 35...
Страница 70: ...Sklop bo nice C t Side Seite Sinistro Page 70 72 Authentic 35...
Страница 71: ...Prednica i vrata Face Avant Front Door Vorderseite T r Parte anteriore e sportello Page 71 72 Authentic 35...
Страница 72: ...Plamen d o o Njema ka ulica 36 P P 209 34000 Po ega Croatia Page 72 72 Authentic 35...