Space heating capacities
The size of the heated place depends on the heating conditions and thermal insulation.
Subject to the heating conditions with individual heat sources having the rated output of 8
kW, it is possible to heat up the following space volumes:
Occasional heating or heating at intervals should be considered as less favourable or even
unfavourable heating conditions.
Chimney selection
Chimney dimensioning to DIN 4705 should be based on the following data:
36
under favourable conditions
160 m
under less favourable conditions
105 m
under unfavourable conditions
75 m
3
3
3
Rated heating output in
[kW]
Flue gas flow rate
in (m)
Mean flue gas temperature
Minimum required negative pressure in the chimney
at rated output
[p]
Minimum required negative pressure in the chimney
[p]
at 0.8-times rated output
8
8,06
0,12
0,10
kW
g/s
290
°C
mbar
mbar
Remember
:
•
When loading the stove, make sure to load a quantity of fuel that is most suitable in respect
of the actual heating requirements.
•
While reloading, make sure that the top plate air supply controls are closed.
•
After reloading, set the air supply controls to a sufficiently open position until bright fire is
developed. Only then, set the air control to the position corresponding to the desired heating
output.
•
Strictly observe these installation and operating instructions, paying special attention to
setting the air controls to proper position to ensure clean (full) fuel combustion and clean glass.
•
Install the stove in a room of adequate size to ensure that the rated output of the stove
meets the heating requirements of the room.
•
Avoid operation at minimum output. Over the night, leave the air supply controls open to
the extent as necessary to have sufficient ember next morning to restart the fire with dry kindling
wood and small logs.
Содержание GLAS AMITY
Страница 1: ...GLAS AMITY 02 2009 SRB...
Страница 2: ......
Страница 40: ...120 mm 2 20 33 cm 2 3 cc 2 5 5 kg 2 cc 2 4 kg 40...
Страница 41: ...2 3 4 5 1 2 8 kW II 41...
Страница 42: ...3 4 mm 1 3 15 8 kW 160 m3 105 m3 75 m3 42...
Страница 43: ...DIN 4705 kW m p p 0 8 8 8 06 0 12 0 10 kW g s 290 C mbar mbar 44 6 120 8 PLAMEN 43 397...