The manufacturer shall not be liable for claims of any type based on operation contrary to 

the intended use.

2.2 Personnel qualification

WARNING!

Risk of injury should qualification be insufficient!

Improper handling can result in considerable injury and damage to equipment.

 

The activities described in these operating instructions may only be carried 

out by skilled personnel who have the qualifications described below.

 

Keep unqualified personnel away from hazardous areas.

Skilled personnel

Skilled personnel are understood to be personnel who, based on their technical training, 

knowledge of measurement and control technology and on their experience and 

knowledge of country-specific regulations, current standards and directives, are capable of 

carrying out the work described and independently recognising potential hazards.

Special operating conditions require further appropriate knowledge, e.g. of aggressive 

media.

2.3 Special hazards

WARNING!

 

For hazardous media such as oxygen, acetylene, flammable or toxic gases or 

liquids, and refrigeration plants, compressors, etc., in addition to all stand-

ard regulations, the appropriate existing codes or regulations must also be 

followed.

WARNING!

To ensure safe working on the instrument, the operating company must 

ensure

 

that suitable first-aid equipment is available and aid is provided whenever 

required.

 

that the operating personnel are regularly instructed in all topics regarding 

work safety, first aid and environmental protection and knows the operating 

instructions and, in particular, the safety instructions contained therein.

Содержание FOS01

Страница 1: ...PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de Instruction Manual FOS01 Optoelectronic Levelswitch...

Страница 2: ...afety 5 3 Specifications 9 4 Design and function 10 5 Transport packaging and storage 11 6 Commissioning operation 12 7 Maintenance and cleaning 13 8 Faults 14 9 Warranty 15 10 Dismounting return and...

Страница 3: ...led personnel at any time Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work The manufacturer s liability is void in the case of any damag...

Страница 4: ...vance can result in serious injury and or damage to equipment Further important safety instructions can be found in the individual chapters of these operating instructions 2 1 Intended use This instru...

Страница 5: ...egulations current standards and directives are capable of carrying out the work described and independently recognising potential hazards Special operating conditions require further appropriate know...

Страница 6: ...ening voltages on the instrument WARNING Residual media in dismounted instruments may result in a risk to people the environment and the system Take sufficient precautionary measures Do not use this i...

Страница 7: ...awings Materials Sensor Tip Electronics housing Stainless steel 1 4571 Quartz Stainless steel 1 4301 Electrical Data Supply voltage DC 24 V 25 30 Supply current max 40 mA Power consumption 1 W Output...

Страница 8: ...conductance and dielectric constant of the liquid Integrated electronics include limit sensing and self calibration The output is an open collector pnp transistor 4 2 Instrument design The sensor is...

Страница 9: ...on mechanical shock putting it down hard Soot vapour dust and corrosive gases Potentially explosive environments flammable atmospheres Store the instrument in its original packaging in a location that...

Страница 10: ...hen withdrawn from a glass of water WARNING The electrical connection must only be carried out by qualified skilled personnel Observe the relevant VDE regulations 6 1 Installation instructions tank or...

Страница 11: ...reen white O C pnp Load Switching direction The switching direction is factory set Model Function Condition LED Output transistor Ext relay SE Normally open immersed on switch on connect SE Normally o...

Страница 12: ...nstrument see chapter 10 2 Return 8 Faults Faults Possible causes Measures No function No power supply Measure power supply check connection to cable or plug No function in spite of liquid level chang...

Страница 13: ...depressurised 10 2 Return WARNING Absolutely observe when shipping the instrument All instruments delivered to PKP Prozessmesstechnik GmbH must be free from any kind of hazardous substances acids base...

Страница 14: ...uid This is registered by the receiver which then initiates a switching process at the PNP transistor output of the device which is indicated directly by a green LED Typical applications The field of...

Страница 15: ...Min distance to an opposite surface 10 mm 20 mm if electropolished Mounting position any Dimensions Order Code Order number FOS01 Optoelectronic level switch 3 2 1 1 0 Process connection 1 M16 x 1 5 2...

Отзывы: