PKP FOS01 Скачать руководство пользователя страница 3

 1. General information

 

The mini limit switch described in the operating instructions has been manufactured 
using state-of-the-art technology. 
All components are subject to stringent quality and environmental criteria during 
production. Our management systems are certified to ISO 9001.

 

These operating instructions contain important information on handling the mini limit 
switch. Working safely requires that all safety instructions and work instructions are 
observed.

 

Observe the relevant local accident prevention regulations and general safety 
regulations for the mini limit switch's range of use.

 

The operating instructions are part of the instrument and must be kept in the immediate 
vicinity of the mini limit switch and readily accessible to skilled personnel at any time.

 

Skilled personnel must have carefully read and understood the operating instructions, 
prior to beginning any work.

 

The manufacturer's liability is void in the case of any damage caused by using the 
product contrary to its intended use, non-compliance with these operating instructions, 
assignment of insufficiently qualified skilled personnel or unauthorised modifications to 
the mini limit switch.

 

The general terms and conditions contained in the sales documentation, shall apply.

 

Subject to technical modifications.

 

Further information: 

- Internet address:

www.pkp.de

- Application concultant:

Tel.: 

(+49) 6122 – 70 55 0

Fax: 

(+49) 6122 – 70 55 50

E-Mail: 

[email protected]

Explanation of symbols

WARNING!

... indicates a potentially dangerous situation, which can result in serious 

injury or death, if not avoided.

CAUTION!

... indicates a potentially dangerous situation, which can result in light injuries 

or damage to equipment or the environment, if not avoided.

Содержание FOS01

Страница 1: ...PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de Instruction Manual FOS01 Optoelectronic Levelswitch...

Страница 2: ...afety 5 3 Specifications 9 4 Design and function 10 5 Transport packaging and storage 11 6 Commissioning operation 12 7 Maintenance and cleaning 13 8 Faults 14 9 Warranty 15 10 Dismounting return and...

Страница 3: ...led personnel at any time Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work The manufacturer s liability is void in the case of any damag...

Страница 4: ...vance can result in serious injury and or damage to equipment Further important safety instructions can be found in the individual chapters of these operating instructions 2 1 Intended use This instru...

Страница 5: ...egulations current standards and directives are capable of carrying out the work described and independently recognising potential hazards Special operating conditions require further appropriate know...

Страница 6: ...ening voltages on the instrument WARNING Residual media in dismounted instruments may result in a risk to people the environment and the system Take sufficient precautionary measures Do not use this i...

Страница 7: ...awings Materials Sensor Tip Electronics housing Stainless steel 1 4571 Quartz Stainless steel 1 4301 Electrical Data Supply voltage DC 24 V 25 30 Supply current max 40 mA Power consumption 1 W Output...

Страница 8: ...conductance and dielectric constant of the liquid Integrated electronics include limit sensing and self calibration The output is an open collector pnp transistor 4 2 Instrument design The sensor is...

Страница 9: ...on mechanical shock putting it down hard Soot vapour dust and corrosive gases Potentially explosive environments flammable atmospheres Store the instrument in its original packaging in a location that...

Страница 10: ...hen withdrawn from a glass of water WARNING The electrical connection must only be carried out by qualified skilled personnel Observe the relevant VDE regulations 6 1 Installation instructions tank or...

Страница 11: ...reen white O C pnp Load Switching direction The switching direction is factory set Model Function Condition LED Output transistor Ext relay SE Normally open immersed on switch on connect SE Normally o...

Страница 12: ...nstrument see chapter 10 2 Return 8 Faults Faults Possible causes Measures No function No power supply Measure power supply check connection to cable or plug No function in spite of liquid level chang...

Страница 13: ...depressurised 10 2 Return WARNING Absolutely observe when shipping the instrument All instruments delivered to PKP Prozessmesstechnik GmbH must be free from any kind of hazardous substances acids base...

Страница 14: ...uid This is registered by the receiver which then initiates a switching process at the PNP transistor output of the device which is indicated directly by a green LED Typical applications The field of...

Страница 15: ...Min distance to an opposite surface 10 mm 20 mm if electropolished Mounting position any Dimensions Order Code Order number FOS01 Optoelectronic level switch 3 2 1 1 0 Process connection 1 M16 x 1 5 2...