Devices of the DV08 series may only be installed by suitable trained specialist personnel
who are able to install the devices properly. Qualified personnel are those persons who
are familiar with the assembly, installation and commissioning of devices of this type and
who are approbriately qualified.

Inward Monitoring

Please check directly after delivery the device for any transport damages and deficiencies.
Additional with reference to the accompanying delivery note the number of parts must be
checked.
Claims for replacement or goods which relate to transport damage can only be considered
valid if the delivery company is notified without delay.

Functional description

The flow meter DV08 is used for quantitative flow measurement of viscous liquids. The
liquid flow causes two screw spindles to rotate in opposite directions. A magnetic pre-ten -
sioned hall sensor located outside the flow chamber detects the screw flanks and gener-
ates a flow-proportional frequency signal. Two pulses corresponds to one revolution of the
screws and thus to a certain measuring volume. There are no magnets in the flow cham-
ber.

Installation and commissioning

The Dv08 flow meters are in-line devices with either an aluminium adapter with female
thread or a SAE flange with female thread on the process side. No special inlet or outlet
sections are required.

Check that the maximum pressures and temperatures specified for the devices are
not   exceeded   by   the   pressures   and   temperatures   in   the   process   and   that   the
materials   used   in   the   device   for   the   parts   in   contact   with   the   product   are   not
attacked by the medium.

Make sure that the pipes have been cleaned and flushed prior to installation and
that there are no foreign objects in the pipe.

Pressure surges caused by sudden changes in flow may damage the unit. Care
must therefore be taken to open valves slowly to avoid pressure surges.

DV08 Instruction manual  04/2019

page  3

Содержание DV08

Страница 1: ...Manual DV08 Screw spindle volumetric flow meter for highly viscous liquids PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email i...

Страница 2: ...l use of insufficiently qualified personnel and unau thorized modification of the device Proper Usage The flow meters of the DV08 series are used to measure and display the flow rates of vis cous self...

Страница 3: ...hall sensor located outside the flow chamber detects the screw flanks and gener ates a flow proportional frequency signal Two pulses corresponds to one revolution of the screws and thus to a certain m...

Страница 4: ...ulse Pulses Litre G 1 1 4 140 13 1 76 3 G 1 3 5 350 29 0 34 5 G 1 5 5 550 48 6 20 6 G 1 8 0 800 72 0 13 9 G 2 10 0 1000 103 6 9 7 G 2 15 0 1500 133 0 7 5 G 2 25 0 2500 238 8 4 2 The push pull output I...

Страница 5: ...the permanently programmed end value can be assigned to any flow value on site Programming 1 Set the maximum flow rate in the system 2 Apply a pulse of a least 0 5 s duration to pin 2 or white strand...

Страница 6: ...rate in the system 2 Apply a pulse of a least 0 5 s duration to pin 2 or white strand with cable outlet e g by jumper to supply voltage or pulse from PLC Immediately after program ming the sensor swit...

Страница 7: ...quency setpoint flow rate in the system 2 Apply a pulse of a least 0 5 s duration to pin 2 or white strand with cable outlet e g by jumper to supply voltage or pulse from PLC The electronics is now pr...

Страница 8: ...the flow rate and the viscosity of the liquid to be measured Higher viscosities result in higher pressure loss Higher viscosities than listed here are easily possible but require a higher pumping cap...

Страница 9: ...DV08 Instruction manual 04 2019 page 9...

Страница 10: ...f the measured value If the flow ranges are limited to 20 80 FS the measurement erors are reduced If the medium has a vis cosity 170 m2 s the accuracy is also improved Test viscosities were 2 22 170 m...

Страница 11: ...l rep resents a pre defined volume of product The flowmeter doesn t have to be taken out of the pipe system for changing the pick up system because the pick up is hermetically sealed from the medium T...

Страница 12: ...h Pull cube plug IR pulse output Push Pull round plug M12x1 M5 frequency converter programmable 0 2 kHz M6 switch output limit programmable M7I with F I converter output 4 20 mA M7U with F U converter...

Страница 13: ...k GmbH Borsigstr 24 D 65205 Wiesbaden S 49 0 6122 7055 0 49 0 6122 7055 50 info pkp de www pkp de PKP Process Instruments Inc 10 Brent Drive Hudson MA 01749 S 1 978 212 0006 1 978 568 0060 info pkp us...

Отзывы: