PKP DV08 Скачать руководство пользователя страница 2

Table of Contents

Safety Information..................................................................................................................2
Functional description............................................................................................................3
Installation and commissioning..............................................................................................3
Output signals........................................................................................................................4
Pressure loss.........................................................................................................................8
Accuracy...............................................................................................................................10

Safety Information

General Instructions

To ensure safe operation, the device should only be operated according to the specifica -
tions   in   the   instruction   manual.   The   requisite   Health   &   Safety   regulations   for   a   given
application must also be observed. This statement also applies to the use of accessories.
Every person who is commissioned with the initiation or operation of this device must have
read and understood the operating instructions and in particular the safety instructions! 

The liability of the manufacturer expires in the event of damage due to improper use, non-
observance of this operating manual, use of insufficiently qualified personnel and unau-
thorized modification of the device. 

Proper Usage

The flow meters of the DV08 series are used to measure and display the flow rates of vis -
cous, self-lubricating liquids. Any other use is considered improper.

In   particular,   applications   in   which   shock   loads   occur   (for   example,   pulsed   operation)
should be discussed and checked in advance with our technical staff.

The devices of the DV08 series must not be used as the sole agents to preventing dan-
gerous conditions on machines and systems. Machines and systems must be designed in
such a way that faulty conditions lead to a dangerous situation for the operating person -
nel.

Dangerous substances

For dangerous media such as e.g. Oxygen, Acetylene, flammable or toxic substances as
well as refrigeration systems, compressors, etc. must comply with the relevant regulations
beyond the general rules. 

Qualified Personnel

DV08 Instruction manual  04/2019

page  2

Содержание DV08

Страница 1: ...Manual DV08 Screw spindle volumetric flow meter for highly viscous liquids PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email i...

Страница 2: ...l use of insufficiently qualified personnel and unau thorized modification of the device Proper Usage The flow meters of the DV08 series are used to measure and display the flow rates of vis cous self...

Страница 3: ...hall sensor located outside the flow chamber detects the screw flanks and gener ates a flow proportional frequency signal Two pulses corresponds to one revolution of the screws and thus to a certain m...

Страница 4: ...ulse Pulses Litre G 1 1 4 140 13 1 76 3 G 1 3 5 350 29 0 34 5 G 1 5 5 550 48 6 20 6 G 1 8 0 800 72 0 13 9 G 2 10 0 1000 103 6 9 7 G 2 15 0 1500 133 0 7 5 G 2 25 0 2500 238 8 4 2 The push pull output I...

Страница 5: ...the permanently programmed end value can be assigned to any flow value on site Programming 1 Set the maximum flow rate in the system 2 Apply a pulse of a least 0 5 s duration to pin 2 or white strand...

Страница 6: ...rate in the system 2 Apply a pulse of a least 0 5 s duration to pin 2 or white strand with cable outlet e g by jumper to supply voltage or pulse from PLC Immediately after program ming the sensor swit...

Страница 7: ...quency setpoint flow rate in the system 2 Apply a pulse of a least 0 5 s duration to pin 2 or white strand with cable outlet e g by jumper to supply voltage or pulse from PLC The electronics is now pr...

Страница 8: ...the flow rate and the viscosity of the liquid to be measured Higher viscosities result in higher pressure loss Higher viscosities than listed here are easily possible but require a higher pumping cap...

Страница 9: ...DV08 Instruction manual 04 2019 page 9...

Страница 10: ...f the measured value If the flow ranges are limited to 20 80 FS the measurement erors are reduced If the medium has a vis cosity 170 m2 s the accuracy is also improved Test viscosities were 2 22 170 m...

Страница 11: ...l rep resents a pre defined volume of product The flowmeter doesn t have to be taken out of the pipe system for changing the pick up system because the pick up is hermetically sealed from the medium T...

Страница 12: ...h Pull cube plug IR pulse output Push Pull round plug M12x1 M5 frequency converter programmable 0 2 kHz M6 switch output limit programmable M7I with F I converter output 4 20 mA M7U with F U converter...

Страница 13: ...k GmbH Borsigstr 24 D 65205 Wiesbaden S 49 0 6122 7055 0 49 0 6122 7055 50 info pkp de www pkp de PKP Process Instruments Inc 10 Brent Drive Hudson MA 01749 S 1 978 212 0006 1 978 568 0060 info pkp us...

Отзывы: