Flow Measurement and Monitoring

DV01

Gear Wheel Flow Sensor
for Viscous Liquids
for OEM Applications

for media with viscosities
between 20-4000 cSt

low-cost version

aluminium- or
stainless steel version

low pressure loss

high compressive strength

small mounting dimensions

any flow direction

measuring ranges: 0,02...4 l/min up to 1...200 l/min

P

max

: 200 bar, T

max

: 80 °C

Description:

The DV01 measuring system consists of a pair of gearwheels
which,   according   to   the   gear   wheel   pump   principle   are
rotated by the flowing liquid.
The gear wheel bearings are constructed as radial and axial
plain bearings (in the case of the DV01.1 and DV01.3, the
DV01.2 uses ball bearings). A magneto resistive measuring
system   hermetically   sealed   from   the   measuring   chamber
senses the rotation of the gear wheels and converts it into a
pulse train. The gear wheel flow meter DV01 causes a very
low pressure drop and makes especially little noise.

Typical applications:

The gear wheel flow meters DV01 are mainly used for con-
sumption   measurement,   the   control   of   dosing   applications
and for monitoring lubricating points. Because of their small
dimensions and their low price they are especially suited for all
kinds of OEM applications.

PKP Prozessmesstechnik GmbH

Borsigstr. 24 • D-65205 Wiesbaden

S

 +49 (0) 6122-7055-0 • 

T

 +49 (0) 6122 7055-50

 [email protected] •   www.pkp.de

20181128

Содержание DV01

Страница 1: ...Instruction Manual DV01 Gear wheel flow sensor for viscous liquids PKP Prozessmesstechnik GmbH Borsigstraße 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de ...

Страница 2: ...sonnel and unau thorized modification of the device Proper Usage The float type flow meters DS10 are designed to monitor continuous flow rates of liquids or gases which do not attack the device materials All other usage is regarded as being improper and outside the scope of the device In particular applications in which shock loads occur for example pulsed operation should be discussed and checked...

Страница 3: ...idered valid if the delivery company is notified without delay General Information Please observe all instructions in this operating manual to ensure trouble free operation of the flow sensors PKP accepts no liability for damage caused by non compliance with these instructions The devices my only be opened within the warranty period after consultation and approval by PKP Functional Description Ins...

Страница 4: ... built in meter should be accessible for visual inspection at any time during operation Attention In the event of damage to the gear wheel flow meter a pressure safety device must be provided in the system to prevent the maximum permissible pressure of the volume sensor or other components in the system from being exceeded pressure relief valves It must be ensured that the flow meters are only hel...

Страница 5: ...n the piping system before installing the gear wheel flow meter Connect the piping to the inlet and outlet of the meter Follow the instructions of the respective manufacturer During installation make sure that no sealant enters the inside of the pipes Attention The gear wheel flow meter must not be braced during installation After commissioning the system check all connections for leaks Plate conn...

Страница 6: ...y or very high loads This avoids major damage which could be causes for example by blocking the bearings Return Shipment When returning devices to the factory please note that inspections and repairs will only be carried out if a safety data sheet of the medium used is enclosed and the devices have been flushed beforehand In case of non observance the goods will be returned carriage forward These ...

Страница 7: ...al and axial plain bearings in the case of the DV01 1 and DV01 3 the DV01 2 uses ball bearings A magneto resistive measuring system hermetically sealed from the measuring chamber senses the rotation of the gear wheels and converts it into a pulse train The gear wheel flow meter DV01 causes a very low pressure drop and makes especially little noise Typical applications The gear wheel flow meters DV...

Страница 8: ...m DV01 3A b 90 mm t 100 mm h 73 mm DV01 4A b 120 mm t 170 mm h 105 mm Order Code Order number DV01 Gear wheel flow sensor 1A 0 0 Measuring ranges 0A 0 02 4 l min aluminium 0E 0 02 4l min stainless steel 1A 0 25 10 l min aluminium 1E 0 25 10 l min stainless steel 2A 0 16 16 l min aluminium 3A 1 65 l min aluminium 4A 1 200 l min aluminium Display 0 without display DVA prepared for plug on display DV...

Отзывы: