Commissioning

Depending on the type of connection, the device is connected to the system via a connec-
tion plate or by means of pipe connections located in the housing.

Attention:

 

Only pipes and connections that are approved for the expected pressure

range   may  be   used.   The   instructions   of   the   respective   manufacturer   must   be  
observed.
The device must be installed in such a way that it is not subjected to any  imper-

missible vibrations.

Installation  above   hot  parts  is not   permitted  as  any  leaking  liquids may  ignite.  
During   commissioning,   the   device   must   be   checked   for   leaks   under   operating  
conditions.

Pipe and Plate Connection

Thoroughly clean the piping system before installing the gear wheel flow meter.

Connect the piping to the inlet and outlet of the meter. Follow the instructions of the
respective manufacturer.

During installation, make sure that no sealant enters the inside of the pipes.

Attention:

 

The gear wheel flow meter must not be braced during installation.

After commissioning the system, check all connections for leaks.

Plate connection

Before mounting the gear wheel flow meter, sufficiently clean the piping system.

Attach the connection plate to the intended position in the system.

Attention:

 

Make sure that the seals are seated correctly! The connection surface 

must be free of dirt, paint residues etc. during installation!

Tightening Torques for the Connection Plates

Nominal size

DV01.1A/E

DV01.3A

DV01.4A

Tightening torque Nm

-

120

-

DV01 Instruction manual  09/2019

page  5

Содержание DV01

Страница 1: ...Instruction Manual DV01 Gear wheel flow sensor for viscous liquids PKP Prozessmesstechnik GmbH Borsigstraße 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de ...

Страница 2: ...sonnel and unau thorized modification of the device Proper Usage The float type flow meters DS10 are designed to monitor continuous flow rates of liquids or gases which do not attack the device materials All other usage is regarded as being improper and outside the scope of the device In particular applications in which shock loads occur for example pulsed operation should be discussed and checked...

Страница 3: ...idered valid if the delivery company is notified without delay General Information Please observe all instructions in this operating manual to ensure trouble free operation of the flow sensors PKP accepts no liability for damage caused by non compliance with these instructions The devices my only be opened within the warranty period after consultation and approval by PKP Functional Description Ins...

Страница 4: ... built in meter should be accessible for visual inspection at any time during operation Attention In the event of damage to the gear wheel flow meter a pressure safety device must be provided in the system to prevent the maximum permissible pressure of the volume sensor or other components in the system from being exceeded pressure relief valves It must be ensured that the flow meters are only hel...

Страница 5: ...n the piping system before installing the gear wheel flow meter Connect the piping to the inlet and outlet of the meter Follow the instructions of the respective manufacturer During installation make sure that no sealant enters the inside of the pipes Attention The gear wheel flow meter must not be braced during installation After commissioning the system check all connections for leaks Plate conn...

Страница 6: ...y or very high loads This avoids major damage which could be causes for example by blocking the bearings Return Shipment When returning devices to the factory please note that inspections and repairs will only be carried out if a safety data sheet of the medium used is enclosed and the devices have been flushed beforehand In case of non observance the goods will be returned carriage forward These ...

Страница 7: ...al and axial plain bearings in the case of the DV01 1 and DV01 3 the DV01 2 uses ball bearings A magneto resistive measuring system hermetically sealed from the measuring chamber senses the rotation of the gear wheels and converts it into a pulse train The gear wheel flow meter DV01 causes a very low pressure drop and makes especially little noise Typical applications The gear wheel flow meters DV...

Страница 8: ...m DV01 3A b 90 mm t 100 mm h 73 mm DV01 4A b 120 mm t 170 mm h 105 mm Order Code Order number DV01 Gear wheel flow sensor 1A 0 0 Measuring ranges 0A 0 02 4 l min aluminium 0E 0 02 4l min stainless steel 1A 0 25 10 l min aluminium 1E 0 25 10 l min stainless steel 2A 0 16 16 l min aluminium 3A 1 65 l min aluminium 4A 1 200 l min aluminium Display 0 without display DVA prepared for plug on display DV...