background image

Table of Contents

Safety Information..................................................................................................................2
Functional description............................................................................................................3
Construction...........................................................................................................................3
Installation..............................................................................................................................4
Assembly................................................................................................................................5
Electrical connection..............................................................................................................6
Wirings...................................................................................................................................6
Commissioning.......................................................................................................................8
Measuring operation..............................................................................................................8
Maintenance and cleaning.....................................................................................................9
Return shipment to PKP Prozessmesstechnik......................................................................9
Pressure loss.......................................................................................................................10

Safety Information

General Instructions

To ensure safe operation, the device should only be operated according to the specifica -
tions   in   the   instruction   manual.   The   requisite   Health   &   Safety   regulations   for   a   given
application must also be observed. This statement also applies to the use of accessories.
Every person who is commissioned with the initiation or operation of this device must have
read and understood the operating instructions and in particular the safety instructions! 

The liability of the manufacturer expires in the event of damage due to improper use, non-
observance of this operating manual, use of insufficiently qualified personnel and unau-
thorized modification of the device. 

Proper Usage

The devices of the DM01A series are used for reliable magnetic inductive flow measure-
ment of conductive liquids which do not attack the materials used. Any other use of the
device is not permitted and is outside the scope of application.

The devices of the DM01A should not be used as sole monitoring devices in order to
detect or even avoid dangerous operating states in plants and machines. The plant or
machine itself must  be  planned and constructed  in  such a way that critical conditions
which pose a danger to man and the environment are excluded from the outset.

Dangerous substances

For dangerous media such as e.g. Oxygen, Acetylene, flammable or toxic substances as
well as refrigeration systems, compressors, etc. must comply with the relevant regulations
beyond the general rules. 

DM01A Instruction manual  07/2019

page  2

Содержание DM01A

Страница 1: ...Instruction Manual DM01A Compact magnetic inductive flowmeter PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de...

Страница 2: ...ent of damage due to improper use non observance of this operating manual use of insufficiently qualified personnel and unau thorized modification of the device Proper Usage The devices of the DM01A s...

Страница 3: ...n a magnetic field B An electric ally conductive medium V flows through the measuring tube The positive and negative charge carriers are oppos itely deflected A voltage U is generated at right angles...

Страница 4: ...rised and has cooled down Caution Risk of malfunction due to external magnetic fields Magnetic fields close to the device can cause malfunctions and should be avoided Ensure that no external magnetic...

Страница 5: ...t devices are too close together operation of both devices may be impaired due to mutual interference Assembly The DM01A is installed directly into the pipeline The compact design and light weight of...

Страница 6: ...M01A Connection Screw the coupling socket of the connection cable to the plug of the DM01A Tighten the knurled nut of the coupling socket with a maximum torque of 1 Nm Wirings Pinout The pinout differ...

Страница 7: ...s of several DM01A may not be connected in parallel Ensure that the maximum signal current of 25 mA is not exceeded Use of frequency and analogue output Push Pull Ensure that the maximum signal curren...

Страница 8: ...de the green LED flashes proportional to the measured flow For the human eye the flashing is no longer visible from a frequency of 30 40 Hz The green LED then seems to light up permanently DM01A with...

Страница 9: ...ents for cleaning Return shipment to PKP Prozessmesstechnik Please observe the following instructions before returning the device Clean the device thoroughly This is of extreme importance if the mediu...

Страница 10: ...Pressure loss Measuring range 0MG 0 05 2 l min Measuring range 01G 0 1 5 l min Measuring range 02G 0 25 20 l min DM01A Instruction manual 07 2019 page 10...

Страница 11: ...Measuring range 03G 1 50 l min Measuring range 05G 4 200 l min Measuring range 06G 5 250 l min DM01A Instruction manual 07 2019 page 11...

Страница 12: ...1 4 A push pull frequency output is available as an out put signal An analogue 4 20 mA or 0 5 10 V signal is also available as an option Advantages no moving parts therefore the DM01A is maintenance a...

Страница 13: ...C276 2 4819 FKM for measuring range 0MG 01G 02G only Measuring range connection size 0MG 0 05 2 l min G 3 8 male from 0 1 l min in tol 01G 0 1 5 l min G 1 2 male from 0 25 l min in tol 02G 0 25 20 l...

Отзывы: