background image

Qualified Personnel

The DM01A devices may only be installed by trained, qualified personnel who are able to
mount   the   devices   correctly.   Qualified   personnel   are   persons,   who   are   familiar   with
assembling, installation, placing in service and operating these devices and who are suit-
ably trained and qualified.

Inward Monitoring

Please check directly after delivery the device for any transport damages and deficiencies.
Additional with reference to the accompanying delivery note the number of parts must be
checked.
Claims for replacement or goods which relate to transport damage can only be considered
valid if the delivery company is notified without delay.

Functional description

The magnetic inductive flow sensor func-
tions according to the induction principle.
A DC voltage is generated by the move-
ment of a conductor in a magnetic field.

The measuring tube of the DM01A is loc-
ated in a magnetic field (B). An electric-
ally   conductive   medium   (V)   flows

through

 the measuring tube. The positive

and negative charge carriers are oppos-
itely deflected.
A voltage (U) is generated at right angles
to the magnetic field, which is picked up
by   the   two   electrodes.   Thereby,   the
induced voltage is proportional to the average flor velocity of the liquid. 
The electronics of the DM01A converts the induced voltage into a flow-proportional fre-
quency signal.

Construction

The measuring tube with its earthing sleeves and electrodes
passes through the housing and forms the external process
connection of the DM01A. A magnetic field for the measure-
ment  process is  generated  inside  the  housing,  which  also
contains the sensor and signal conditioning circuitry. The two
stainless steel electrodes  are located  in the  middle of  the
measuring tube between the earthing sleeves.
The DM01A does not need any moving parts to make meas-
urements.  The  inside of  the  measuring tube  is completely
open, allowing the fluid to flow unhindered through the meas-
uring tube.

DM01A Instruction manual  07/2019

page  3

Содержание DM01A

Страница 1: ...Instruction Manual DM01A Compact magnetic inductive flowmeter PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de...

Страница 2: ...ent of damage due to improper use non observance of this operating manual use of insufficiently qualified personnel and unau thorized modification of the device Proper Usage The devices of the DM01A s...

Страница 3: ...n a magnetic field B An electric ally conductive medium V flows through the measuring tube The positive and negative charge carriers are oppos itely deflected A voltage U is generated at right angles...

Страница 4: ...rised and has cooled down Caution Risk of malfunction due to external magnetic fields Magnetic fields close to the device can cause malfunctions and should be avoided Ensure that no external magnetic...

Страница 5: ...t devices are too close together operation of both devices may be impaired due to mutual interference Assembly The DM01A is installed directly into the pipeline The compact design and light weight of...

Страница 6: ...M01A Connection Screw the coupling socket of the connection cable to the plug of the DM01A Tighten the knurled nut of the coupling socket with a maximum torque of 1 Nm Wirings Pinout The pinout differ...

Страница 7: ...s of several DM01A may not be connected in parallel Ensure that the maximum signal current of 25 mA is not exceeded Use of frequency and analogue output Push Pull Ensure that the maximum signal curren...

Страница 8: ...de the green LED flashes proportional to the measured flow For the human eye the flashing is no longer visible from a frequency of 30 40 Hz The green LED then seems to light up permanently DM01A with...

Страница 9: ...ents for cleaning Return shipment to PKP Prozessmesstechnik Please observe the following instructions before returning the device Clean the device thoroughly This is of extreme importance if the mediu...

Страница 10: ...Pressure loss Measuring range 0MG 0 05 2 l min Measuring range 01G 0 1 5 l min Measuring range 02G 0 25 20 l min DM01A Instruction manual 07 2019 page 10...

Страница 11: ...Measuring range 03G 1 50 l min Measuring range 05G 4 200 l min Measuring range 06G 5 250 l min DM01A Instruction manual 07 2019 page 11...

Страница 12: ...1 4 A push pull frequency output is available as an out put signal An analogue 4 20 mA or 0 5 10 V signal is also available as an option Advantages no moving parts therefore the DM01A is maintenance a...

Страница 13: ...C276 2 4819 FKM for measuring range 0MG 01G 02G only Measuring range connection size 0MG 0 05 2 l min G 3 8 male from 0 1 l min in tol 01G 0 1 5 l min G 1 2 male from 0 25 l min in tol 02G 0 25 20 l...

Отзывы: