- 27 -
connect to the terminal block the power cable.
The power supply cable must be of
H07-RNF
type, with approved
minimum cross section as prescribed by the specific directive.
The electrical outlet must be easy to access, no moving should be
necessary.
It is mandatory that the electrical system is equipped with a
ground connection.
The appliance must be part of an equipotential system. The connection is
done on terminal marked with symbol which you will find near the cable
clamp. The section of the equipotential wire must be at least 10 mm
2
.
The equipotential symbol is showed in the following figure.