PixelRange PixelLine Micro W Скачать руководство пользователя страница 4

4

Troubleshooting

Fixture remains at blackout when illumination expected 

•  The display panel (or at least one of its decimal points) 

should be lit - if not, check the input power and fuse. 

•  If live DMX is connected, the right hand decimal point 

on the display should flash - if not, check the DMX 

cable and the desk output. 

•  Check that the selected 

MODE

 matches the desk per-

sonality being used. 

•  The master intensity channel for the current mode may 

be set at zero. For 

DMX

 mode, check the setting of 

PERS

 > 

MINT

.  

•  Ensure that only one DMX device is set as master.
•  Standalone chase effects: Effects programmed using 

PROG

 > 

C1

 and 

C2

 but the fixture is not in 

MODE

 > 

EF M

 mode. Check also that 

MODE

 > 

PROG

 > 

LEVL

 

is not set at zero.

•  Standalone RGB mixing: Colour values set within 

MAN

 

section but the fixture is not in 

MODE

 > 

MANU

 mode.

Fuse access

The single fuse is located on the underside panel of the 

fixture. 

To remove the fuse

Using a flatblade screwdriver, push down the fuse cap 

and then twist it anti-clockwise until it disengages from the 

holder.

Weight 

  Fixture and yoke: 

2.1Kg (4.6lbs)  

Power

  Input voltage:  

90 to 264V AC, 47 to 63Hz autosensing

  Earth leakage 

0.12mA

  Connectors: 

Neutrik

®

 PowerCon

®

 (see first page for details)  

   Power requirements: 

@ 230V/50Hz 

@ 115V/60Hz

    

Standby

 

  2 watts 

 

  2 watts

    

Maximum (const.)

 

  66 watts   

  66 watts

    

Start up (peak*)

 

  <40 amps  

  <20 amps

* The peak value occurs only at first power up 

and lasts only for a period measured in micro-

seconds. Adjustments may need to be made to 

supply circuit breakers when multiple fixtures 

are daisy-chained, causing them all to draw the 

peak simultaneously.  

Approvals

Miscellaneous

  Enclosure rating:  

IP20 (not protected against moisture ingress)

  Control input: 

USITT DMX512 (input connector pin out below)

  

Specifications

Dimensions

PIN 

Ground

PIN 2

Data 

PIN 3

Data +

PIN 5

Not used

PIN 4

Not used

Documentation by 

Corporate Text & Design

 (www.ctxd.com)

Release 1.0d

Fuse type: 20mm 2A (T2AH)  

anti-surge, ceramic body

203mm

(8”)

167m

m

(6

”)

1

/

2

86mm

(3

”)

3

/

8

110mm

(4 ")

1

/

3

150mm

(5 ”)

7

/

8

Note: The dimensions shown above 

relate to the main fixture body. The 

yoke knob extends 10mm (3/8”) 

beyond the stated width of the fixture.

Using master mode to drive other units

This unit can control any number of other Pixel Range 

fixtures via DMX links, without the need for a control desk.    
1  Set this unit as 

master

 (

PERS

 > 

DATA

 > 

MAST

) and 

ensure all others are set to 

slave

 (

PERS

 > 

DATA

 > 

SLAV

). Connect all fixtures via DMX daisy-chain.

2  Set each slave to 

Mode

 > 

DMX

.  

3  Set each slave DMX address (using 

ADDR

 > 

DMX

) ac-

cording to the following:

  18 cells are output in groups of 3 DMX channels to 

give RGB values per cell (54 channels in total). Set the 

address of each slave fixture according to which of the 

18 cells you want them to appear within, or to begin 

with (for multi-cell fixtures): (

A001

 for cell 1, 

A004

 for 

cell 2, ... 

A052

 for cell 18). Set RGBA slave fixtures to 

3 channel mode (using 

PERS

 > 

RES

 > 

3ch

).

4  Set the master to 

Mode

 > 

EF m

 (

the master unit’s 

DMX address is ignored).

 On the master, choose 

the required effects to display and send to the slave 

fixtures using 

PROG

 > 

C1

 and 

C2

.

www.pixelrange.com

UK +44 (0)1905 363600

[email protected]

USA +1 865 588 7660

[email protected]

Отзывы: