PixelRange PixelArt Скачать руководство пользователя страница 4

4

PixelArt Batten signal cabling

•  Industry standard Category 5e or 6 (CAT 5e or CAT 6) twisted pair network cable terminated at either 

end with standard RJ45 connectors or Neutrik

®

 EtherCon

®

 NE8MC (for more robust linking). Either cross-

over or straight wired cables may be used for each link - every batten configures the signals accordingly.

•  Maximum length of 100 metres (328 feet) between any two battens (or between the Video Mapper and a 

batten). Every PixelArt Batten reconditions the signal before transmitting it to the next.

•  A maximum of 100 PixelArt fixtures are permissible within a single installation.
• 

IMPORTANT: Do not connect ANY PixelArt Batten cabling to an Ethernet network. Such an interconnection 

will not cause damage but will result in both the PixelArt system and the network functioning incorrectly.

 

LINK

LIN

K

A

C

TIVITY

A

C

TIVITY

ER

R

O

R

ERR

OR

SOURCE

SOURCE

MAX PO

WER 100W

90 – 240V 

A

C

47 – 63H

z

FUSE 3.15A SLO

W

 B

L

O

W

B

A

www

.pix

elrange

.com

PU

SH

PU

SH

LINK

LINK

A

CTIVITY

A

CTIVITY

ERR

OR

ERR

OR

SOURCE

SOURCE

MAX PO

WER 100W

90 – 240V 

A

C

47 – 63H

z

FUSE 3.15A SLO

W BLO

W

B

A

www

.pix

elrange

.com

PU

SH

PU

SH

LINK

LINK

A

CTIVITY

A

CTIVITY

ERR

OR

ERR

OR

SOURCE

SOURCE

MAX PO

WER 100W

90 – 240V 

A

C

47 – 63Hz

FUSE 3.15A SLO

W BLO

W

B

A

www

.pix

elrange

.com

PU

SH

PU

SH

From Video Mapper MAIN port 

(or previous PixelArt fixture)

To port A of the 

next PixelArt 

fixture

MAIN

STANDBY

Standby cabling

You have the option to run a link cable from the last PixelArt fixture 

back to the STANDBY port of the Video Mapper. This provides a 

failsafe loop against link cable failure. In such an occurrence, the 

system will automatically recognise the loss of signal and re-route 

from the other direction up to the lost cable. The battens will all 

reconfigure themselves accordingly and operate around the failure 

with no loss of output on either side of the break.

IMPORTANT: When setting up a new 

installation, do not connect the standby 

cable to the Video Mapper until the 

PixelArt fixtures have been taken out 

of auto-numbering mode. Otherwise 

the battens will incorrectly begin auto 

numbering themselves from both ends 

of the installation.

      

or

To the 

STANDBY port 

of the Video 

Mapper

(see below)

For more 

robust linking, 

use Neutrik

®

 EtherCon

®

 

NE8MC connector carriers

Each PixelArt Batten 

uses its position 

within the daisy 

chain cabling link 

to automatically 

determine its own 

number within the 

installation. No 

switch settings are 

used. 

Содержание PixelArt

Страница 1: ...r video and power cabling page 7 Video Mapper startup page 8 Video Mapper menu page 8 PixelArt Setup Utility page 9 PixelArt Setup Utility five key functions page 10 Crosshairs grids and solid colour...

Страница 2: ...tab and click the Discover Fixtures button to determine the current arrangement of the connected PixelArt fixtures see page 10 9 In the PixelArt Setup Utility select the Fixture Mapping tab and where...

Страница 3: ...he omega brackets using the supplied bolts wash ers and Nyloc nuts 3 Offer the bracket to the screws so that the curved slots engage then rotate the bracket anti clockwise Tighten the screws 4 Insert...

Страница 4: ...S H LINK LINK ACTIVITY ACTIVITY ERROR ERROR SOURCE SOURCE MAX POWER 100W 90 240V AC 47 63Hz FUSE 3 15A SLOW BLOW B A www pixelrange com P U S H P U S H From Video Mapper MAIN port or previous PixelArt...

Страница 5: ...ower cabling and status indicators IMPORTANT Do not connect more than 20 PixelArt Battens in a single power daisy chain LINK LINK ACTIVITY ACTIVITY ERROR ERROR SOURCE SOURCE MAX POWER 100W 90 240V AC...

Страница 6: ...hub Use CAT5e or CAT6 cable see crossover note above Depending on its configuration the Video Mapper will either attempt to automatically find itself a suit able network address or will use a pre con...

Страница 7: ...DVI D input Video input resolution and frequency The link between the Video Mapper and the PixelArt fixtures has a maximum bandwidth of 120 000 pixels at 25Hz frames per second This equates to a quar...

Страница 8: ...sh to keep after the next power up visit the Configuration option and select Save This is especially vital when changing network ad dresses as it may affect the next power up Pattern Tools Controls th...

Страница 9: ...eo Mapper flash memory Please see the next page for details about how to perform each key function Use this menu to confirm the source video input define the crop area and save all settings to the Vid...

Страница 10: ...the DVI monitor you will see the green outlined crop area change within the total video space to reflect your values This is now the screen area that will be sent to the PixelArt fixtures 4 Fixture m...

Страница 11: ...shairs 2 Select the Crosshair Area option and choose either Absolute or Crop Area 1 as required 3 Select the Crosshair X or Crosshair Y option as appropriate and increase or decrease the position valu...

Страница 12: ...simplify fixture positioning information and also to ensure that the video image remains true regardless of how each PixelArt fixture is arranged In the representations shown here the power cables are...

Страница 13: ...milarly the origin point for each PixelArt fixture is also always in the top left hand corner regardless of their respec tive rotation settings x 0 y 0 1 4 7 10 13 8 9 2 5 3 6 12 11 x 0 y 0 o 90 x 6 y...

Страница 14: ...k adapters including wireless and FireWire links on the computer except the one that is connected to the Video Mapper If the Video Mapper is connected directly to the computer i e not via a network ro...

Отзывы: