Transferrable Installation

1. Measure the cable length required from your mounting location to your power source.

2. Cut the cable to length (if required).

3. Determine where along your cable you want to install a marine grade connector for easy 

connection / disconnection to aid transfer of the RockFLEET from one vessel to another.

4. Install the marine grade connectors.

     a. Cut the cable at the desired connector position, removing any existing connectors from

         the RockFLEET end of the cable

NOTE: If using a RockFLEET with a 30cm cable, it is recommended to re-terminate this cable 

with a new waterproof marine grade connector, ensuring the use of marine grade adhesive 

heat-shrink tubing and conduit to prevent damage to the inner wires or cable.

     b. Connect a marine grade plug to the RockFLEET end of the cable 

     c. Connect the complimentary marine grade socket to the power source end of the cable

     d. Use a marine grade adhesive heat-shrink tubing to prevent the inner wires being exposed

         and prevent water and salt ingress. Apply the marine grade heat-shrink tubing up to and 

         including the end of the connector if possible

     e. Use protective conduit along the length of the cable to provide it protection from damage

5. If additional cabling is required;

     a. Connect the required length of cable onto the end using waterproof connectors

     b. Use a marine grade heat-shrink around the cable join to prevent the inner wires being

         exposed and prevent water and salt ingress

     c. Use protective conduit along the length of the cable to provide it protection from damage

6. Wire the positive (red) and negative (black) cores of the power cable onto your power supply. 

Where possible, connection to the Power Supply should be made below decks where it is not 

exposed to the elements.  Ensure that the termination of the wires to the power supply is 

properly sealed, preventing the inner cores of the wires from being exposed to the elements.     

7. Repeat steps 4c through to step 6 for any additional vessels that will be utilising the 

RockFLEET.

NOTE: It is important to cover the plug of any cable not connected to a RockFLEET, preventing 

water or salt ingress.  Failing to cover the plug when not in use may lead to corrosion and cable 

failure.  

Marine Grade Waterproof Connectors

It is important to use marine grade waterproof connectors for any transferrable installations to 

prevent water or salt ingress on the cables. The Waterproof Deutsch 2-way connector 

(PP2150) is a suitable connector to use when used with marine grade adhesive heat-shrink 

tubing and ideally a connector boot.