M0164B
6
/16
Use and maintenance
9
TECHNICAL DATA
DATA
REFERENCE
VALUE
Mechanism
Oval Gears
Flow Rate
Range
1 – 30 lit/min.
0,26 – 7,9 gal/min.
Operating Pressure
Max
70 bar
Bursting Pressure
Min
210 bar
Storage Temperature
Range
-20 - +80 °C
Storage Humidity
Max
85% RH
Operating Temperature
Range
-10 - +60 °C
Pressure loss with
SAE 10W40 oil at 20°C
(15 l/min)
(bar)
0.7
Accuracy
+/- 1%
Repetitivity
Typical
+/- 0.2%
Partial Indicator
3 + 1 digits
Total Indicator
6 digits
Resolution
(of the indication)
0.1 litres - 0.1 quarts
Connections
Inlet/Outlet
½” BSP - ½” NPT
Weight
0,78 Kg
Packaging Dimensions
160x130x115 mm
Versions
- Indication in litres with GAS threaded inlet and outlet
- Indication in gallons with NPT threaded inlet and outlet
10
PROBLEMS, CAUSES AND SOLUTIONS
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Unsatisfactory
accuracy
Measuring chamber is dirty or clogged Clean the measuring chamber following
the instructions shown in the “disassem-
bly and reassembly” section
Presence of air in the liquid
Identify and eliminate leaks in the suc-
tion lines
Low flow rate
Measuring chamber is dirty or clogged Clean the measuring chamber following
the instructions shown in the “disassem-
bly and reassembly” section
Filter is clogged or dirty
Clean the filter