TECHNICAL DATA
H1
PERFORMANCE SPECIFICATIONS
The performance diagram shows flow rate as a function of back pressure.
Functioning Point Absorption(A)
Flow Rate
(l/min)
Back Pressure
(BAR)
Typical
delivery
configuration
4 met
ers of 3/4”
tub
e
aut
oma
tic dis
-
pensing no
zzle
A
(
Maximum Flow Rate
)
15
52
0,2
B
(Base system)
17
40
0,5
•
•
C
(
By-Pass
)
24
0
1,1
Delivery
Closed
X
Y
A
B
C
0
P (bar)
ATTENTION
The curve refers to the following operating conditions:
Fluid: PETROL,
Temperature: 20° C
Suction conditions: The pipe and the pump position relative
to the fluid level is such that a low pressure of 0.3 bar is
generated at the nominal flow rate.
Under different suction conditions higher low pressure
values can be created that reduce the flow rate compared
to the same back pressure values. To obtain the best perfor-
mance, it is very important to reduce loss of suction pressu-
re as much as possible by following these instructions:
• shorten the suction pipe as much as possible
• avoid useless elbows or throttling in the pipes
• keep the suction filter clean
• use a pipe with a diameter equal to, or greater than,
indicated (see Installation).