IP65 Notice

 

 

 

 

 

 

 

IP65 RATED 

An  IP  rated  lighting  fixture  is  one,  which  is  commonly  installed  in 
outdoor  environments  and  has  been  designed  with  an  enclosure 
that effectively water. The 

International Protection (IP) 

rating system 

is commonly expressed as 

"IP" 

(Ingress Protection) followed by two 

numbers  (i.e.  IP65)  where  the  numbers  define  the  degree  of 
protection.  The  first  digit  (Foreign  Bodies  Protection)  indicates  the 
extent  of  protection  against  particles  entering  the  fixture  and  the 
second  digit  (Water  Protection)  indicates  the  extent  of  protection 
against  water  entering  the  fixture.  An  IP65  rated    lighting  fixture  is 
one,  which  has  been  designed  and  tested  to  protect  against  the 
ingress  of  dust  (6)  and  low-pressure  water  jets  from  any  direction 
(5).

 

 

MARINE / COASTAL  ENVIRONMENT  INSTALLATIONS !

 

Please  note  although  this  fixture  is  IP  rated,  the  fixture  is  NOT 
suitable  for  marine  and/or  coastal  environment  installations. 
Installing this fixture in a marine and/or coastal environment may cause 
corrosion  and/or  excessive  wear  to  the  interior  and/or  exterior 
components  of  the  fixture.  Damages  and/or  performance  issues 
resulting  from  installation  in  a  marine  and/or  coastal  environment 
will  void  the  manufactures  warranty  and  will  NOT  be  subject  to  any 
warranty claims and/or repairs.

 

Содержание PLUSlite First-PL067

Страница 1: ...First PL067 IP65 ParLed User Instructions https www piu39av com pluslite lighting ...

Страница 2: ...n be used in a stand alone mode or connected in a Master Slave configuration This par has multiple operating modes RGBW dimmer mode Static Color mode Auto Run mode Color Macro mode and DMX control This product is intended to be used by professionally trained personnel only and is not suitable for private use These instructions contain important safety information regarding the use and maintenance ...

Страница 3: ...perating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit s weight Also always use a safety cable that can hold 12 times the weight of the unit when installing the fixture The equipment must be installed by a professional and it must be installed in a place where it is out of the reach of people s grasp Ensure ALL c...

Страница 4: ...ufacturer See page 24 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the fixture C The fixtu...

Страница 5: ...ion indicates the extent of protection against water entering the fixture An IP65 rated lighting fixture is one which has been designed and tested to protect against the ingress of dust 6 and low pressure water jets from any direction 5 MARINE COASTAL ENVIRONMENT INSTALLATIONS Please note although this fixture is IP rated the fixture is NOT suitable for marine and or coastal environment installati...

Страница 6: ...FIRST PL067 Layout PL067User Manual Page 4 IP65 Locking Power Connection In Out IP65 Locking Singal 3P Connector In Out LED Display Mode button Up button Down button Enter button ...

Страница 7: ...ing at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The PL067 can be controlled via DMX 512 protocol The PL067 has 2 DMX channel modes The DMX address is set on the back panel of the PL067 Your...

Страница 8: ...rom which thefixture startsto listen to thedigitalcontrolsignalsent outfrom the DMXcontroller The assignment of this starting DMX address is achieved by setting the correct DMX address on the digital control display on the fixture You can set the same starting address for all fixtures or a group of fixtures or set different addresses for each individual fixture Setting all fixtures to the same DMX...

Страница 9: ...r 0 100 0 255 8CH Describe Parameter CH1 Main Dimming 0 255 CH2 Strobe Speed 0 255 CH3 Dimming Mode Macro Color 1 Macro Color 2 Macro Color 3 Macro Color 14 Macro Color 15 Ayto Mode Pluse Mode Gradual Mode 0 10 11 20 21 30 31 40 141 150 151 160 161 190 191 220 221 225 CH4 Mode Speed 0 255 CH5 R Dimming 0 255 CH6 G Dimming 0 255 CH7 B Dimming 0 255 CH8 W Dimming 0 255 ...

Страница 10: ...Describe Parameter D001 DMX 4CH Mode Master Slave Mode 1 512 A001 DMX 8CH Mode Master Slave Mode 1 512 CC70 Auto Mode 0 99 CP70 Pulse Mode 0 99 DE70 Gradually Mode 0 99 R255 R Dimmer 0 255 G255 G Dimmer 0 255 B255 B Dimmer 0 255 W255 W Dimmer 0 255 ST00 Strobe Speed slow fast 0 16 ...

Страница 11: ...the others will react to the controlling units built in programs Any unit can act as a Master or as a Slave however only one unit can be programmed to act as the Master Master Slave Connections and Settings 1 Daisy chain your units via the XLR connector on the rear of the unit Use standard XLR data cables to link your units together Remember that the Male XLR connector is the input and the Female ...

Страница 12: ...Dimensional Drawing FIRST PL067 FIRST PL067User Manual Page 10 NOT TO SCALE unit mm ...

Страница 13: ...solutions Unit not responding to DMX 1 Check that the DMX cables are connected properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are connected Due to fog residue smoke and dust cleaning the internal and external optical lenses must be car ried out ...

Страница 14: ... prior written notice Model FIRST PL067 Voltage LEDs IP Rating Working Position Power Draw Power Linking Weight Dimensions Colors DMX Channels Warranty 100V 240V 50 60Hz 14x 10W 4 in 1 CREE LED s IP65 Any safe working position 140W 20 Fixtures Max 120V 40 Fixtures Max 240V 4 2Kgs 230 x 165 x 300mm RGBW Color Mixing 4 DMX Modes 8 Channel Mode 2 Year https www piu39av com pluslite lighting ...

Отзывы: