Document 15342 Rev D1 07/24/97 P/N 15342:D1
Section One
The ACM-8R Annunciator Control Module
The ACM-8R is an element in the Notifier ACS class of annunciators. It provides the
System 500, System 5000, AFP-200, AM2020, AFP1010 and SFP-1024 Fire Alarm
Control Panels with a relay control module that can be mapped. The relays on this
module can be selected for mapping anywhere in the
System 5000 or System 500 memory map (by groups of
eight).
Features of the ACM-8R
The ACM-8R provides eight Form-C relays with 5 amp
contacts. The relays can be employed to track any 8 point
module in the System 5000 or System 500, or track any
grouping of points in the AM2020 or AFP1010.
Extends capacity of System 5000, System 500, AFP-200
and SFP-1024 by adding a relay per initiating zone.
Extends capacity of AM2020 or AFP1010 by adding 256
relay points (using 32 ACM-8Rs x 8 relays per module).
The ACM-8R provides DIP switch selectable memory
mapping of relays.
The ACM-8R is also provided with removable terminal
blocks for ease of installation and service.
The ACM-8R Annunciator Control Module may be used in combination with a variety
of products on the same EIA-485 bus circuit including AFM Series annunciators, LDM
Series annunciators, LED-10N annunciators and UDACTs (Universal Digital Alarm
Communicator/Transmitter).
EIA-485 bus compatible accessories are designed to provide maximum flexibility to
system configurations. Examples include multiple remote LED annunciators with
customized labels per corresponding area or function, multiple remote graphic annun-
ciators that illustrate building layout and floor plans, remote DACTs for strategic
mounting location near telephone equipment plus remote high current switching relays
for such purposes as fan and damper control, elevator recall and door releasing.
Mounting
The ACM-8R module will mount to CHS-4 chassis or a CHS-4L low-profile chassis
(assumes one of four positions on the chassis) or for remote applications, to an ABS-
8R Annunciator Surface-mount backbox with blank faceplate (18240). The ACM-8R
will also mount to the CAB-500 backbox in the System 500.
Additional References
For more information on annunciator operation under various specific applications,
refer to the respective operating manual:
The AM2020/AFP1010 Operating Manual, Document 15335
The System 5000 Operating Manual, Document 15581
The System 500 Installation Manual, Document 15019
The AFP-200 Instruction Manual, Document 15511
The SFP-1024 Instruction Manual, Document 50475