Pittsburgh 67801 Скачать руководство пользователя страница 3

Page 3

For technical questions, please call 1‑800‑444‑3353.

SKU 67801

5.  Place the unit on the wall a few 

inches to the right of where it 

detected the stud.  Then move it 

slowly from right to left, horizontally 

across the wall and mark the spot 

when stud detects again.  Between 

the two spots is the stud position.

6.  Repeat the process to 

confirm position of studs.

Metal Detection

1.  Slide the switch to the 

“METAL” position.

2.  Press and hold Power Button. 

Calibrate the unit in air away 

from metal objects.

3.  The Power LED lights when the 

detector is ready to operate. 

Position unit flat against wall. 

4.  Slowly slide unit horizontally 

across wall, left to right.  Keep the 

unit base in contact with the wall.  

The Metal LED lights and the unit 

starts emitting a steady tone when it 

detects the edge of a metal object.  

When that happens, mark the spot 

over the top center of the detector.

5.  Place the unit on the wall a few 

inches to the right of where 

it detected the metal object.  

Then move it slowly from right to 

left, horizontally across the wall 

and mark the spot when Metal 

detects again.  Between the two 

spots is the metal object’s position.

6.  Repeat the process to confirm 

position of metal objects.

Voltage Detection

TO PREVENT SERIOUS INJURY AND 

ELECTROCUTION: 

The unit will not detect live wires 

inside metal pipe or metal conduit, 

behind metallic wall covering, or 

behind some plywood or other dense 

materials.  Use extra caution in these 

construction situations.  Always turn 

the power off when nailing, cutting, 

or drilling near electrical wire. 

NOTE: Because the unit is sensitive 

it may indicate metal while passing 

through the air.  Simply release 

Power Button, place on the wall, and 

press Power Button on again.  This 

effectively re‑calibrates the electronics.
The unit detects from 90 to 250 V at 

50 to 60 Hz AC in a HOT unshielded 

electrical wire that is within 1‑1/2″ of 

wall surface.  The sensor is located 

in the center of the back of the unit.
1.  Turn power on in the wall you 

will try to detect voltage in.  

The power must be turned off later 

after detection and before work to 

reduce the risk of accidental shock.

2.  Slide the switch to the 

“VOLT” position. 

3.  Press and hold Power Button. 

Calibrate the unit in air away 

from metal objects.

4.  The Power LED lights when the 

detector is ready to operate. 

Position unit flat against wall. 

5.  Slowly slide unit horizontally 

across wall, left to right.  Keep the 

unit base in contact with the wall.  

The Volt LED lights and the unit 