26
2. Main menu
OMR location (scanner postion)
Here you select the scanner position, all available positions are defined in the Service
menu, here you can only select already defined positions.
001> OMR Location: TOP-REAR
<>=SELECT
Green=CONF. Blue=EXIT Red=GO ON
Scan line increment
To do this measure the minimum distance between the scan lines which are right next to
each other:
• 1/6 Inch
• 1/8 Inch
• 1/10 Inch
•
User Def.
User Def. needs to enter a value for example 3.5mm is set as 350.
Scan line increment
The scan line position number is shown on the far right of the display (see below), BM
(bench mark) being set as 1 (first scan line position). In total there are 31 scan line posi
-
tions available.
The following examples show the first two scan line definitions. BM is permanently 1 and
cannot be modified. The second scan line position (far right “2”) is defined as DVF (divert
finished) in this example. The scan function (i.e. DVF) can be changed by scrolling through
the available scan functions.
BMC1
: [ 1]
<-->=SELECT
Green= CONFIRM
DVF
: [ 2]
<-->=SELECT Green=CONF. Blue=END Red=IGNORE
DVF
: [ 2]i
<-->=SELECT Green=CONF. Blue=END Red=IGNORE
If the current scan line position is to be ignored, choose a not used function and press
RED (Ignore) a small “i” is placed after the number
and confirming with GREEN and the function is ignored.
All available scan functions are listed below.
• BM
• ALW1
• ALW0
•
DVF
•
DVD
•
EOC
• WAS (2-5)
• SI (2-5)
• SSQ
• SF 1-7
• HFL
• HFF
• ST
• Parity Even
• Parity Odd
•
BOC
See chapter 3. Settings for explantion of the different functions.
When all required OMR scan lines have been defined, press BLUE to exit.