background image

PITCO VF SERIES INSTALLATION & OPERATIONAL MANUAL

 

26 

L20-418 Rev 2 (5/16) 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Original instructions. 

 

 

Annual service to this appliance by an authorized person is recommended.  Do not modify this appliance: 
servicing must only be carried out by an authorized person.  For service and parts, minor adjustments, fault 
finding, or if this appliance cannot be adjusted to operate correctly, contact: 
 
 
 
 

 

 

 

 
 

 

In the event of problems with or questions 
about your order, please contact the Pitco 
factory at 
+1 (603) 225-6684 World Wide 
Website Address: www.pitco.com 

In the event of problems with or questions 
about your appliance, please contact the Pitco 
Authorized Service and Parts representative 
(ASAP) covering your area, or contact Pitco at 
the numbers listed to the left.

 

MAILING ADDRESS – P.O. BOX 501, CONCORD, NH 03302-0501 

SHIPPING ADDRESS – 39 SHEEP DAVIS RD., PEMBROKE, NH 03275 

 

Содержание VF35

Страница 1: ...L20 418 Rev 2 5 16 Installation and Operation Manual Covering Models VF35 VF65 Fryers...

Страница 2: ...liance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C...

Страница 3: ...k tank cover workshelf drain board is not a step Serious injury could result from slipping falling or contact with hot liquids WARNING NEVER use the appliance as a step for cleaning or accessing the v...

Страница 4: ...lified personnel WARNING To avoid splashing of hot liquid when installed this fryer must be restrained either in the manner of installation or with adequate ties to prevent tipping WARNING In North Am...

Страница 5: ...LOT FLAME ADJUSTMENT 13 BURNER SYSTEM ADJUSTMENT 13 OPERATION 15 APPLIANCE START UP 17 APPLIANCE SHUTDOWN 18 PREVENTATIVE MAINTENANCE 18 APPLIANCE INSPECTION 19 CLEANING THE COOK TANK 19 CLEANING THE...

Страница 6: ...anual record the following for warranty service or future reference 1 Your Pitco model number 2 Fryer serial numbers Found on the inner door of each fryer 3 The date purchased from your dealer invoice...

Страница 7: ...he necessary height to meet sanitation requirements and assure adequate air supply for electrical component ventilation To level the appliance use the following procedure Required tools Large pair of...

Страница 8: ...25 4 54 1 0 AT BG CY CH CZ DK EE FI FR DE GR HU IE IT LT LU MT NL NO PL RO SI SE SK TR BU G30 I3B P 30 50 25 4 55 0 8 VF655 VF35 19 0 LP16 LP16 Nat G20 G25 G20 G25 G20 G20 20 5 26 5 24 5 10 8 18 5 20...

Страница 9: ...plate which is attached to the inside of the door In North America gas appliances equipped with casters must be installed with connectors that comply with the Standard for Connectors for Movable Gas A...

Страница 10: ...y with AS NZS 5601 0 It is essential that the appliance be operated only when adequate ventilation is provided Your ventilation hood should be properly maintained A qualified installation professional...

Страница 11: ...need to be adjusted to ensure that it will perform as designed A qualified person must perform these adjustments To perform these adjustments the following tools will be needed Manometer Digital Ther...

Страница 12: ...being pressed 7 If the pilot goes out wait 5 minutes and repeat step 4 If after three tries the pilot will not remain lit refer to the TROUBLESHOOTING section of this manual 8 Once a pilot flame has...

Страница 13: ...r optimum flame Refer to the following procedure to adjust the burners 1 Ensure that the gas control valve is shut OFF remove the burner pressure tap plug and connect an accurate pressure gauge range...

Страница 14: ...AUTION If the appliance can t be adjusted to operate properly contact a qualified service person or contact the factory using the contact information on the back of this manual WARNING Before operatin...

Страница 15: ...ITY Lbs kg liter VF35 35 15 9 17 5 VF65 65 29 5 32 4 It is recommended that high quality liquid frying oils be used for longest oil life 1 Verify that the tank interior is clean and free of any constr...

Страница 16: ...Melt the oil shortening by cycling the burners ON for 4 seconds and OFF for 30 seconds repeatedly using the thermostat knob AVOID these conditions Very Hazardous Excessive and large spaces WARNING NEV...

Страница 17: ...tion NEVER overfill appliance baskets Overfilling can result in soggy greasy product When removing baskets from the cook tank shake gently to remove excess oil Never leave a basket over the appliance...

Страница 18: ...king process particles crumbs and crackling collect inside the fry tank reducing product quality and decreasing oil shortening life If you are producing high quantities of fried food and or frying hea...

Страница 19: ...clean out rod remove all the loose debris and scrub all tank surfaces 4 For tougher carbonized oil shortening and carbon buildup scrub tank using a Scotchbrite or other abrasive pad DO NOT use steel...

Страница 20: ...d or frying heavily battered food it may be necessary to clean these components more than once a month BOIL OUT PROCEDURE Wear protective gloves and clothing when cleaning and draining the appliance O...

Страница 21: ...rip on and into the flue Check flue for foreign debris and hood down draft currents Check drain filtration system if equipped for leaks Check for missing appliance parts i e cover strips Check for mis...

Страница 22: ...not to touch the heat tubes since this will measure incorrect temperatures Allow several minutes for the thermometer to equalize with the oil temperature 2 Light the pilot as described in this manual...

Страница 23: ...h temperature limit has tripped please refer to the following procedure to reset the switch Turn the appliance OFF a Allow the appliance ample time to cool to room temperature b Add oil shortening to...

Страница 24: ...limit switch open YES Did high limit switch reset YES Light the pilot Contact a qualified service technician NO NO Does pilot go out when temperature increases YES Do the burners light NO Purge air fr...

Страница 25: ...th Cooking Area Width Cooking Area Depth Overall Height Overall Width Overall Depth Shipping Weight VF35 14 35 6 cm 14 35 6 cm 2 0 3 5 5 1 8 9 cm 47 3 120 1 cm 15 6 39 6 cm 32 81 3 cm 161 lbs 73 kg VF...

Страница 26: ...pliance cannot be adjusted to operate correctly contact In the event of problems with or questions about your order please contact the Pitco factory at 1 603 225 6684 World Wide Website Address www pi...

Отзывы: