Pitco TB-SRTG Скачать руководство пользователя страница 5

TB-SRTG: Gas Floor Model Rethermalizer 

 

 INSTALLATION

 

 

        L20-376, rev. 1 (08/18) 

# Description

TB-SRTG

1 Cleaning brush

Standard 

2 Tube Rack

Optional

3 8 Product Vertical Food Rack

Optional

4 8 Product Rack

Optional

5 6 Product Food Rack

Optional

6 Wide Product Suitcase

Optional

7 Narrow Product Suitcase

Optional

8 Tall Wide Product Suitcase

Optional

9 Tall Narrow Product Suitcase

Optional

10 Wide basket

Optional

11 Narrow Basket

Optional

12 8 Product basket

Optional

13 Gas Quick Disconnect & lanyard

Optional

14 Water Quick Disconnect & Lanyard

Optional

15 1/3 Pan Rails

Optional

16 Combo 12 Product/Tube Rack

*Standard

Accessories

1. INSTALLATION 

 

1.1.  CHECKING YOUR NEW APPLIANCE 

Your new Pitco appliance has been carefully packed 
into one crate. Every effort has been made to ensure 
that it is delivered to you in perfect condition. As you 
unpack your new appliance, inspect each of the 
pieces for damage. If something is damaged, DO 
NOT sign the bill of lading. Contact the shipper 
immediately; the shipper is only responsible for 15 
days after delivery. Check the packing list enclosed 
with your appliance to ensure that you have received 
all the parts to the appliance. If you are missing any 
parts, contact the dealer from whom the appliance 
was purchased. As you unpack the appliance and its 
accessories be careful to keep the weight of the 
appliance evenly distributed.  Refer to the table below 
to identify which accessories should be included with 
your appliance. 
 
Locate your Pitco model number and serial number 
on the inner door of the appliance and the find the 
date purchased.  Write this information on the front 
cover of this manual for future reference. 
 
If you have completed the above steps that are applicable to the appliance you purchased, the 
appliance is now ready to be installed. Although it may be possible for you to install and set up your 
new appliance, it is STRONGLY recommended that you have this done by qualified professionals. A 
qualified professional will ensure that the installation is safe and meets local building and fire codes. 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

WARNING 

DO NOT sit or stand on this appliance. The appliance’s front panel, tank, splash back, tank 
cover, workshelf, drain board is not a step.  Serious injury could result from slipping, falling 
or contact with hot liquids.

 

Содержание TB-SRTG

Страница 1: ... this information and retain this manual for the life of the equipment Model ___________________________ Serial ___________________________ Date Purchased ____________________ ENGLISH Model TB SRTG Floor Model Gas Rethermalizer D E I F I T R E C D E S I G N C I R E T I F E D Model TB SRTG 2 Shown ...

Страница 2: ...ower cord and it is damaged it must be replaced by a Pitco Authorized Service and Parts ASAP company technician or a similarly qualified person in order to avoid a hazard WARNING The power supply must be disconnected before servicing maintaining or cleaning this appliance WARNING The appliance is NOT jet stream approved DO NOT clean the appliance with a water jet WARNING DO NOT attempt to move thi...

Страница 3: ...NG 4 1 5 3 CE GAS TABLE 5 1 6 ELECTRICAL CONNECTIONS 7 1 7 VENTILATION AND FIRE SAFETY SYSTEMS 8 1 8 INSPECTION 9 1 9 INITIAL ADJUSTMENTS 10 1 9 1 FILLING THE APPLIANCE 10 1 9 2 LIGHTING INSTRUCTIONS 10 1 9 3 PILOT FLAME ADJUSTMENT 11 1 9 4 MAIN BURNER SYSTEM ADJUSTMENT 12 1 10 INITIAL CLEANING 13 2 OPERATION 14 2 1 OPERATIONAL FEATURES 14 2 2 FILLING THE APPLIANCE 16 2 2 1 FILLING THE COOKER TANK...

Страница 4: ... 3 CLEANING THE CABINET 19 3 2 MONTHLY PREVENTATIVE MAINTENANCE 19 3 2 1 DELIMING 20 3 3 ANNUAL PERIODIC PREVENTATIVE MAINTENANCE AND INSPECTION 20 3 3 1 TEMPERATURE PROBE HIGH LIMIT PROBE SENSORS 20 3 3 2 CONTROLLER 20 3 3 3 CONTROL PANEL ELECTRICAL COMPONENTS 20 3 3 4 TANK 20 3 3 5 DRAIN SYSTEM 20 3 3 6 GAS COMBUSTION SYSTEM 20 3 4 VENTILATION HOOD 21 4 TROUBLESHOOTING 22 4 1 POWER FAILURE 22 4 ...

Страница 5: ...fter delivery Check the packing list enclosed with your appliance to ensure that you have received all the parts to the appliance If you are missing any parts contact the dealer from whom the appliance was purchased As you unpack the appliance and its accessories be careful to keep the weight of the appliance evenly distributed Refer to the table below to identify which accessories should be inclu...

Страница 6: ... are tight 3 Mount the screws from the inside of the appliance with the nut on the outside bottom of the appliance The nuts have lock washers attached to them therefore it is not necessary to use separate lock washers 4 When all four legs casters are securely mounted stand the unit up being careful not to put too much weight on any one leg Adjust the height and level the appliance by adjusting the...

Страница 7: ...r water pressures a high pressure regulator must be installed to inlet plumbing to avoid damage caused by water hammer The maximum allowable incoming water temperature is 180 F 82 C Have your water tested and record the measured values below 1 4 2 DRAIN CONNECTIONS Each tank has a drain that can be inserted into a drainage system Each tank also has an overflow line The overflow connection is after...

Страница 8: ... comply with the Standard for Movable Gas Appliances ANSI Z21 69 CSA 6 16 latest edition This connection should include a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use With Gas Fuel ANSI Z21 41 CSA 6 9 latest edition When installing a quick disconnect you must also install adequate means for limiting the movement of the appliance without depending on ...

Страница 9: ... A N A N A N A N A N A G31 I3P 14 7 50 25 4 53 LP16 YES 0 6 CZ G20 I2H 16 14 4 20 10 42 N22 YES 1 5 G31 I3P 14 7 50 37 25 4 53 LP16 YES 0 6 DE G20 G25 I2ELL 16 14 4 20 25 10 42 2 58 mm N22 MF28 YES 1 5 1 8 G31 I3P 14 7 50 37 25 4 53 LP16 YES 0 6 DK G20 I2H 16 14 4 20 10 42 N22 YES 1 5 N A N A N A N A N A N A N A N A N A EE G20 I2H 16 14 4 20 10 42 N22 YES 1 5 N A N A N A N A N A N A N A N A N A ES...

Страница 10: ... YES 0 6 LV G20 I2H 16 14 4 20 10 42 N22 YES 1 5 N A N A N A N A N A N A N A N A N A MT N A N A 16 N A N A N A N A N A N A N A G31 I3P 14 7 50 25 4 53 LP16 YES 0 6 NL G25 I2L 16 14 4 25 10 2 58 mm N22 MF28 YES 1 8 G31 I3P 14 7 50 25 4 53 LP16 YES 0 6 NO G20 I2H 16 14 4 20 10 42 N22 YES 1 5 N A N A N A N A N A N A N A N A N A PL G20 I2H 16 14 4 20 10 42 N22 YES 1 5 G31 I3P 14 7 37 25 4 53 LP16 YES ...

Страница 11: ... local and national codes and regulations WARNING The appliance must be grounded in accordance with local code if there is no local code comply with the NEC and ANSI NFPA No 70 latest edition for US and Canadian installations In all other cases refer to local and national codes and regulations To comply with European requirements European models are equipped with an equalization bonding clamp An e...

Страница 12: ...ions Excessive or unbalanced ventilation may cause drafts which could interfere with proper operation of the pilot and burners Leave at least 18 inches 45 72cm of open space between the flue of the appliance and the intake of the exhaust hood WARNING If your appliance is uses line current it is equipped with an oil proof electrical supply cord with a three prong safety plug This is to protect oper...

Страница 13: ... After the appliance is in its permanent location check the levelness Any additional leveling that is necessary can be performed as previously described Ensure that the probe and high temperature limit is in place and secure Check the high limit bulb mounting screws to ensure that they are tight Review the installation portion of this manual and ensure that all steps have been followed and execute...

Страница 14: ...hes the level sensors 1 9 2 LIGHTING INSTRUCTIONS There is nothing to manually light on the electronic ignition system Pilot ignition is performed and controlled by the electronic ignition system Refer to the following instructions to light the appliance 1 Open the gas supply valves to the appliance 2 Turn the gas valve knob to the ON position 3 If the appliance is equipped with a I 0 ON OFF switc...

Страница 15: ...er 0 15 A or greater for CE units 2 Adjust the current reading to the required level by adjusting the pilot flame Remove the pilot adjustment screw cap screw to expose the pilot adjustment screw Turning the pilot adjustment screw clockwise will decrease the size of the pilot flame and flame sense current Turning the pilot adjustment screw counterclockwise will increase the pilot flame size and the...

Страница 16: ...reading of the installed pressure gauge should not drop from the required installation pressure Any loss of pressure indicates inadequate supply line installation which will cause poor performance of all appliances during peak usage 3 The installed pressure gauge should be the same 0 1 W C 25mbar 02kPa as that marked on the data plate on the inside door of the appliance If the pressure is correct ...

Страница 17: ...omplete rinse the inside of the tank thoroughly with cool water Continue to rinse the tank until the cleaner has been completely and thoroughly rinsed from the tank 5 Using a clean dry cloth wipe out all of the water CAUTION Be careful not to disturb the probe and high temperature limit during operation and cleaning of this appliance WARNING Wear protective gloves and clothing when cleaning and dr...

Страница 18: ...c control type should be included with this manual Refer to that manual prior to operating this appliance 2 1 OPERATIONAL FEATURES The diagram below outlines some of the key operational components of your appliance Refer to the following sections of this manual to learn more about these features ...

Страница 19: ...nd eventually exit the appliance through the drain outlet 7 High Temperature Reset Button This button may need to be pressed in the event that the high temperature limit has tripped 8 Tank Cover shown in UP position Keeps heat inside and debris outside of the cook tank 9 Tank Cover Latch shown with Cover in the Down position Holds the tank cover in the up position when adding or removing product f...

Страница 20: ...ow of water During normal operation the automatic fill system will maintain the water level at the proper height NOTE If the water control system turns on while the main burners are running the main burners will turn off This is Normal and will not affect the operation of the appliance When the tank refills to the high level probe the main burners will relight 2 2 2 FILLING THE COOKER TANK WITHOUT...

Страница 21: ... each button and display 6 The appliance is now on and heating the water in the cook tank 2 4 TEMPERATURE CONTROL PROGRAMMING A jumper wire must be installed between terminals 5 and 3 on the back of the controller Controller is non programmable without the wire installed 2 4 1 PROGRAMMING SET TEMPERATURE Press display shows SP1 Set Temperature mode Set Temperature is programmed using this function...

Страница 22: ... of the product bag creating good heat transfer and ultimately shorter retherm times Do NOT retherm in boiling water Boiling water increases your energy and water consumption and furthermore this appliance is NOT recommended for boiling Always follow proper food safety Refer to FDA and the food manufacturer s guidelines for proper handling of the vacuum sealed product 2 6 APPLIANCE SHUTDOWN There ...

Страница 23: ...rub the tank basket hanger baskets and temperature probe using a Scotchbrite or other abrasive pad with a commercial type cleaner specifically designed for cleaning and sanitizing food contact surfaces Follow the directions and familiarize yourself with the safe use of this cleaner prior to using it to clean the appliance Care must be taken to remove all the foreign material on the tank and on com...

Страница 24: ...ng properly Ensure the overlay surface is free of damage Check for loose electrical connections Verify simmer temperature at 1 above controller probe if necessary check probe resistance Check liquid level control to ensure that the appliance stops heating when the water level is low When the water level is low the appliance should automatically refill to the sensors 3 3 3 CONTROL PANEL ELECTRICAL ...

Страница 25: ...afely and properly Exhaust gas temperatures can reach as high as 1000 F 538 C Therefore it is very important to install a fire safety system Your ventilation system should be designed to allow for easy cleaning Frequent cleaning of the ventilation system and the appliance will reduce the chances of fire Additional information can be obtained from CSA International 8501 East Pleasant Valley Rd Clev...

Страница 26: ... following procedure to reset the switch 1 Turn the appliance off 2 Allow the appliance ample time to cool to room temperature 3 Add water to the cook tank as needed 4 Press the high temperature reset button if equipped 5 The high limit switch is now reset and the appliance is ready for start up 4 3 DRAIN VALVE INTERLOCK If your appliance is equipped with a drain valve interlock circuit the applia...

Страница 27: ...ve Actions No power to appliance Check main building power supply Circuit Breaker tripped Reset circuit breaker Controller not turned on Turn on controller Power Cord loose or not connected Connect power cord Water not turned on Turn on water Lower water level sensor is wet Dry off sensor Dirty upper water level sensor Clean upper water level sensor Insufficient mineral content in water Add 1 8 cu...

Страница 28: ...Website Address www pitco com In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area or contact Pitco at the numbers listed to the left MAILING ADDRESS P O BOX 501 CONCORD NH 03302 0501 SHIPPING ADDRESS 39 Sheep Davis Road Pembroke NH 03275 ...

Отзывы: