Solstice I12 Cooking Computer
Pitco P/N 60149514
L20-379 Rev 0
Page 8 of 24
On-demand filtering may be used to perform filters during Early Bird or Deferral time periods. Once
successfully complete, the filter will be logged and the filter event will be satisfied. Filtering outside
of these time periods will not be logged or satisfy any filter requirements.
If a drain is open erroneously or for maintenance purposes, answer NO (key [0]) to all questions.
No data logging or filter requirements will occur. It is assumed the same batch of removed oil will
be returned to the vat by the operator.
2.4.1 Disposing
On-demand filtering may also be used to dispose oil. Start a filter as described above. When
is displayed, press key [0] to skip. The display will change
to
, press key [6] to begin the dispose process.
The display will show
until the drain is closed. Close the drain once all oil has
been drained from the vat and turn the control OFF. All filter data from the disposed batch of
oil will be saved and a separate log will be started for the new batch of oil.
The Start-up Filter requirement after a Dispose event will not be enforced if new oil is raised to
operating temperature within 1 hour after disposing.
2.5 Filter
Deferring
If allowed, Start-up and Time Trigger filter events may be deferred and performed at a later time.
When a filter event occurs and the prompt
is displayed, the
operator may press key [0] to defer. The length of deferral and number of times the operator may
defer is configurable (sections 6.4 & 6.5).
At the end of the deferral period, the operator will be prompted again to perform filtering. An on-
demand filter may also be performed any time during the deferral period and prior to the next
prompt to satisfy the conditions for the filter event requirement.