Solstice I12 Cooking Computer
Pitco P/N 60149514
L20-379 Rev 0
Page 18 of 24
6.2
Set the Filter Temperature:
Display will show
. Enter a new value with cook keys, and press
to save, or skip with current value.
Note: 275°F is the factory default. Entries of 230 to 300 °F are permitted. Vat temperatures above this
value will start, or continue the OIL LIFE timer counter.
6.3
Set the Filter Duration:
Display will show
. Enter a new value in minutes 0:mm with cook
keys, and press
to save, or skip with current value.
Note: 10 minutes is the factory default.
Entries of 1 to 59 are permitted.
6.4
Set the Deferal Time:
Display will show
. Enter a new value in hours h:00 with the cook
keys, (h:mm) and press
to save, or skip with current value.
The factory default is 1 hour. Range of adjustment is :30 to 2:59.
6.5
Set the Deferal Counts:
Display will show
. Use the [0] key to scroll through the range of
permitted range of values (0 to 3). When the correct value shows, press the
to save, or skip
without changing current value.
Note: If this value is set to zero, deferrals are disabled. The practical effect is to force a filter on every
active trigger without the option of deferrals. The factory default is 1.
6.6
Set the Early Bird Time:
Display will show
. Enter a new value with cook keys, (h:00) and
press
to save, or skip with current value.
Note: If set to 0, filter operations before the trigger time will not be counted.
Note:
The factory default is -2 hour. Range of adjustment is (0 – 2) hours. These are negative time
values.